17
The timer can be used to either turn the unit on or off after a number of
elapsed hours. The timer is adjustable between 1-24 hours in one hour
increments.
How to set the unit to automatically turn on:
1) Press the
Timer button while the portable air conditioner and
remote are powered off. The On Timer [
] indicator will be blinking.
2) Use the
Up and Down buttons to set the number of hours
you want to pass before the unit turns on.
3) Wait until the On Timer [
] indicator stops blinking. After the
selected time passes, the unit will automatically turn on.
How to set the unit to automatically turn off:
1) Press the
Timer button while the portable air conditioner and
remote are powered on. The Off Timer [
] indicator will be blinking.
2) Use the
Up and Down buttons to set the number of hours
you want to pass before the unit turns off.
3) Wait until the Off Timer [
] indicator stops blinking. The unit will
automatically turn off after the selected time passes.
Draining the Unit
When the portable air conditioner is in cooling mode or dehumidify
mode, it will remove moisture from the air. The condensed water
from the air will be collected in an internal reservoir and will be
evaporated and exhausted out of the exhaust hose. However, in
very humid conditions, the internal reservoir may fill completely.
This causes the air conditioner to turn off to avoid overflowing the
internal reservoir. The
indicator will appear on the Control
Panel LCD.
Direct drainage option
You can attach a drain hose to the drain port for continuous
drainage.
1. Remove the rubber drain plug from the drain port.
2. Connect a drain hose to the drain port.
The portable air conditioner will now drain through the drain hose.
Please note that this unit has no drain pump; all water will drain
with gravity only, i.e., only “downhill.”
Timer
NOTE: To cancel the timer,
press the
Timer button
twice, or press the
Power button once
.