Wa t e r Pu m P
OP e r a t O r 's ma n u a l
17
a I r f I l t e r
Level 1.
Tools required: Cleaning brush, 25 or 50 mm (1 or 2 in.)
Parts required: REPOWER AIR & FUEL FILTER KIT.
1. Close choke (Cold Start Position [ ]). This prevents dirt from
entering the carburetor throat when the air lter is removed. Brush
accumulated dirt from air cleaner area.
2. Remove air lter cover. Brush dirt from inside cover.
3. Remove air lter and lightly brush debris from lter. Replace lter
if it is damaged, fuel soaked, very dirty, or the rubber sealing edges
are deformed.
4. If lter can be reused, be certain it:
• Fits tightly in the air lter cavity.
• Is installed with the original side out.
5. Install air lter cover.
NOTE
Carburetor adjustment may be needed after air lter cleaning/re-
placement. See Carburetor Adjustment Section.
f u e l f I l t e r
Level 1.
Tools required: 200-250 mm (8-10 in.) length of wire with one end
bent into a hook, clean rag, funnel, and an approved
fuel container.
Parts required: REPOWER AIR & FUEL FILTER KIT.
DANGER
Fuel is VERY ammable. Use extreme care when mixing, storing
or handling.
1. Use a clean rag to remove loose dirt from around fuel cap and
empty fuel tank.
2. Use the “fuel line hook” to pull the fuel line and lter from the
tank.
3. Remove the lter from the line and install the new lter.