Echo WP-1000 T1E Water Pump User Manual


 
Wa t e r Pu m P
OP e r a t O r 's ma n u a l
15
s t a r t I n g w a r m e n g I n e
The starting procedure is the same as Cold Start except DO NOT close
the choke.
1. Move ignition switch (A) to start, move throttle lever (D) towards
engine to idle position. Pull starter handle (E) and engine should
start. Do not use choke (B).
NOTE
If engine does not start after 5 pulls, use Cold Start Procedure.
s t o p p I n g e n g I n e
1. Move throttle lever (D) towards engine to idle position and allow
engine to return to idle before shutting engine off.
2. Move ignition switch (A) to “Stop” position.
WARNING
If engine does not stop when stop switch is moved to STOP posi-
tion, close choke - COLD START position - to stall engine. Have
your ECHO dealer repair stop switch before using unit again.
A
B
C
E
A
D
A
B
c o l d w e a t h e r o p e r a t I o n
Pumps will not freeze when running. However, in freezing weather, re-
move drain plug (A) and prime port plug (B) and drain the water from
pump completely after use. All hoses exposed to freezing temperatures
should also be drained, Before restarting the pump, replace the drain
plug and ll plug securely, making sure the gaskets are in place and in
good condition to prevent air entry into the pump. Prime the pump.