SEER EER
Rated
ARI
Capacity
1
Rated
Sensible
Capacity
CFM
Refrigeration Connections
Required
Indoor Coil
Orifi ce
2
Outdoor Indoor
Piston or Field
Installed TXV
Factory Installed
TXV
Suction Liquid Suction Liquid
2AC14*18P
E(C,U,M,H)1P23 E(C,U,M,H)2T23 14.0 12.2 19,000 14,100 650 3/4 3/8 3/4 3/8 A2TXV01
E(C,U,M)1P24 E(C,U,M,H)2T24 13.5 12.0 18,400 13,600 650 3/4 3/8 3/4 3/8 A2TXV01
2AC14*24P
E(C,U,M,H)1P23 E(C,U,M,H)2T23 14.2 12.8 23,600 18,600 850 3/4 3/8 3/4 3/8 A2TXV01
E(C,U,M)1P24 E(C,U,M,H)2T24 13.5 12.3 22,600 17,850 850 3/4 3/8 3/4 3/8 A2TXV01
E(C,U,M,H)1P29 E(C,U,M,H)2T29 14.2 12.9 23,800 18,800 050 3/4 3/8 3/4 3/8 A2TXV01
2AC14*30P E(C,U,M,H)1P36 E(C,U,M,H)2T36 14.0 12.6 28,600 20,900 1,050 3/4 3/8 3/4 3/8 A2TXV01
2AC14*36P
E(C,U,M,H)1P36 E(C,U,M,H)2T36 14.2 12.6 34,600 25,250 1,250 3/4 3/8 3/4 3/8 A2TXV01
E(C,U,M,H)1P43 E(C,U,M,H)2T43 14.5 12.7 34,800 25,400 1,250 3/4 3/8 3/4 3/8 A2TXV01
2AC14*42P
E(C,U,H)1P49 E(C,U,H)2T49 14.0 12.5 40,000 29,700 1,450 7/8 3/8 7/8 3/8 A2TXV02
E(C,U,H)1P62N E(C,U,H)2T62N 14.0 12.4 40,000 28,200 1,450 7/8 3/8 7/8 3/8 A2TXV02
E(C,U,H)1P62D E(C,U,H)2T62D 14.0 12.5 40,000 29,200 1,450 7/8 3/8 7/8 3/8 A2TXV02
2AC14*48P
E(C,U,H)1P49 E(C,U,H)2T49 14.0 12.3 48,000 34,560 1,650 7/8 3/8 7/8 3/8 A2TXV02
E(C,U,H)1P62N E(C,U,H)2T62N 14.0 12.3 48,000 34,560 1,650 7/8 3/8 7/8 3/8 A2TXV02
E(C,U,H)1P62D E(C,U,H)2T62D 14.2 12.3 48,000 34,560 1,650 7/8 3/8 7/8 3/8 A2TXV02
2AC14*60P RBCS2M6OV-IP
3
RBCS2M60V-2T 14.0 12.0 54,000 41,600 1,950 7/8** 3/8 7/8 3/8 A2TXV02
* - B or L
** Rated with 1-1/8 vapor line
1
Certifi ed in accordance with Unitary Air Conditioner Certifi cation Program, which is based on ARI Standard 210/240.
2
Required to achieve ARI rating.
3
3.5 ton only rated with variable speed air handler on indoor side to obtain 14 SEER.
Cooling Performance - Extended Ratings
Outdoor
Model
Indoor Model
Indoor
Temp
DB/WB
(˚F)
Outdoor Temp - DB (˚F)
65 82 95 105 115
Btuh S/T W Btuh S/T W Btuh S/T W Btuh S/T W Btuh S/T W
2AC14*18P E(U,C,M)2T23 80/67 21,900 .67 1,420 20,900 .72 1,600 20,400 .74 1,680 19,400 .77 1,740 18,000 .77 1,800
2AC14*24P E(U,C,M)2T23 80/67 25,500 .72 1,580 24,300 .77 1,780 23,700 .79 1,860 22,500 .82 1,930 20,900 .83 1,990
2AC14*30P E(U,C,M)2T36 80/67 31,000 .67 1,920 29,500 .71 2,170 28,800 .73 2,280 27,400 .76 2,370 25,300 .76 2,440
2AC14*36P E(U,C,M)2T36 80/67 37,400 .66 2,310 35,700 .70 2,620 34,800 .73 2,740 33,100 .75 2,850 30,600 .76 2,940
2AC14*42P E(U,C,M)2T49 80/67 43,700 .66 2,790 41,700 .70 3,150 40,700 .73 3,300 38,600 .75 3,420 35,800 .76 3,530
2AC14*48P E(U,C,M)2T49 80/67 52,000 .65 3,290 49,600 .69 3,720 40,400 .72 3,900 46,000 .74 4,050 42,600 .75 4,180
2AC14*60P RBCS2M6OV 80/67 58,100 .70 3,750 55,400 .75 4,270 54,000 .77 4,490 51,300 .80 4,671 47,500 .81 4,838
* - B or L