Ducane (HVAC) 2AC14 Air Conditioner User Manual


 
2AC14 Air Conditioner
seer
14
Accessories
Kit Number Description Used with
Hard Start 12W19 (Factory Installed) 2AC14(B,L)18, 24, 30, 42
Hard Start 12W20 2AC14(B,L)36, 48, 60
Low Pressure Switch 14W08 All models
High Pressure Switch 14W09 All models
Low Ambient 14W11 All models
Crankcase Heater 14W04 2AC14(B,L)18, 24, 30, 42
Crankcase Heater 14W05 2AC14(B,L)36, 48, 60
Short Cycle Protection 14W07 All models
Liquid Line Solenoid 20443001 All models
Compressor Sound Blanket 14W00 2AC14(B,L)18, 24, 30, 42
Compressor Sound Blanket 14W03 2AC14(B,L)36, 48, 60
TXV Kit A2TXV01 2AC14(B,L)18, 24, 30, 36
TXV Kit A2TXV02 2AC14(B,L)42, 48, 60
Sound Ratings
Model No. Sound Rating dBA
2AC14*18P 80
2AC14*24P 80
2AC14*30P 79
2AC14*36P 80
2AC14*42P 76
2AC14*48P 78
2AC14*60P 80
Model
Number
Indoor Air Handler
SEER EER
Rated
ARI
Capacity
1
Rated
Sensible
Capacity
CFM
Ref. Connections
Required
Indoor
Coil
Orifi ce
2
Outdoor Indoor
Piston or Field Installed TXV Factory Installed TXV Suct. Liq. Suct. Liq.
2AC14*60P
E(C,U,M,H)1P62C E(C,U,M,H)2T62C 13.0 11.5 53,500 43,500 1,950 7/8 3/8 7/8 3/8 A2TXV02
E(C,U,M,H)1P62D E(C,U,M,H)2T60D 13.0 11.5 53,000 43,000 1,950 7/8 3/8 7/8 3/8 A2TXV02
E(C,U,M,H)1P62C+MPGAV125 E(C,U,M,H)2T62C+MPGAV125 13.5 11.5 54,000 45,000 1,950 7/8 3/8 7/8 3/8 A2TXV02
* - B or L
1
Certifi ed in accordance with Unitary Air Conditioner Certifi cation Program, which is based on ARI Standard 210/240.
2
Required to achieve ARI rating.
Cooling Performance with Air Handlers & Furnaces 60
35183-1_AAE_2AC14_DCN.indd 735183-1_AAE_2AC14_DCN.indd 7 10/15/07 4:43:47 PM10/15/07 4:43:47 PM