2AC14 Air Conditioner
seer
14
Model Number Guide
2 AC 14 B 36 P - 1 A
2 -R22 Minor Revision Code
Split Condensing Unit Major Revision Code
14 - 14 SEER Nominal
Voltage
P - 208-230V/60Hz/1Ph
B = Wire Grill
L = Louvered
Nominal Capacity
36 - 36,000 Btuh
Model Volts/Hz/Phase
Voltage
Range
Min.
Circuit
Amp.
Max.
Over-
current
Device
(amps)
Compressor Fan Motor
Refrig.
Charge
(oz.)
Weight (lbs.)
Rated
Load
(amps)
Locked
Rotor
(amps)
Type
Rated
Load
(amps)
Rated
HP
Nom.
RPM
2AC14*18P 208-230/1/60 197-253 9.7 15 6.9 35 Recip 1.1 1/10 1075 106 185
2AC14*24P 208-230/1/60 197-253 11.6 20 8.4 39 Recip 1.1 1/10 1075 129 201
2AC14*30P 208-230/1/60 197-253 15.2 25 11.3 51 Recip 1.1 1/5 1075 154 227
2AC14*36P 208-230/1/60 197-253 17.2 30 12.9 61 Scroll 1.1 1/5 1075 185 226
2AC14*42P 208-230/1/60 197-253 21.5 35 16.2 82 Recip 1.2 1/4 1075 204 262
2AC14*48P 208-230/1/60 197-253 22.6 35 17.1 100 Scroll 1.2 1/4 1075 208 261
2AC14*60P 208-230/1/60 197-253 28.8 50 21.4 137 Scroll 2.0 1/3 1075 264 270
Physical and Electrical