CoolingPerformancewithAirHandlersandFurnaces(30)
** = B, L, BC, LC
* = B, L
Indoor Model
Variable
Speed
Furnace
SEER EER
Rated
ARI
Capacity
1
Rated
Sensible
Capacity
CFM
Refrigerant
Connection
Refrigerant
Line Size
Indoor
Metering
Device
Piston or Field
Installed TXV
Factory
Installed TXV
Outdoor Indoor
Suction
Liquid
Req'd
Indoor
2
Orifice
Optional
Field
Installed
Orifice
Suction
Liquid
Suction
Liquid
RBCS2M30C****P RBCS2M30C****T --- 13.00 11.50 29,000 21,800 900
3/4
3/8
3/4
3/8 3/4 3/8 .070 A2TXV01
RBCS2M36V****P --- --- 14.00 12.00 29,000 21,800 900
3/4
3/8
3/4
3/8 3/4 3/8 .070 A2TXV01
E(C,H,M,U)1P23NA E(C,M,U)2T23NA CMPEV050 13.50 11.50 28,200 21,200 1000
3/4
3/8
3/4
3/8 3/4 3/8 .070 A2TXV01
E(C,H,M,U)1P23NA E(C,M,U)2T23NA CMPEV075 13.50 11.50 28,200 21,200 1000
3/4
3/8
3/4
3/8 3/4 3/8 .070 A2TXV01
E(C,H,M,U)1P23NA E(C,H,M,U)2T23NA MPGAV050 14.00 11.50 28,200 21,200 1000
3/4
3/8
3/4
3/8 3/4 3/8 .070 A2TXV01
E(C,H,M,U)1P23NA E(C,H,M,U)2T23NA MPGAV075 14.00 11.50 28,200 21,200 1000
3/4
3/8
3/4
3/8 3/4 3/8 .070 A2TXV01
E(C,H,M,U)1P23NB E(C,H,M,U)2T23NB CMPEV0100 13.50 11.50 28,200 21,200 1000
3/4
3/8
3/4
3/8 3/4 3/8 .070 A2TXV01
E(C,H,M,U)1P23NB E(C,H,M,U)2T23NB MPGAV100 14.00 11.50 28,200 21,200 1000
3/4
3/8
3/4
3/8 3/4 3/8 .070 A2TXV01
E(C,H,M,U)1P29NA E(C,H,M,U)2T29NA CMPEV050 13.50 12.00 29,000 21,800 1000
3/4
3/8
3/4
3/8 3/4 3/8 .070 A2TXV01
E(C,H,M,U)1P29NA E(C,H,M,U)2T29NA CMPEV075 13.50 12.00 29,000 21,800 1000
3/4
3/8
3/4
3/8 3/4 3/8 .070 A2TXV01
E(C,H,M,U)1P29NA E(C,H,M,U)2T29NA MPGAV050 14.00 12.00 29,000 21,800 1000
3/4
3/8
3/4
3/8 3/4 3/8 .070 A2TXV01
E(C,H,M,U)1P29NA E(C,H,M,U)2T29NA MPGAV075 14.00 12.00 29,000 21,800 1000
3/4
3/8
3/4
3/8 3/4 3/8 .070 A2TXV01
E(C,M,U)1P30NA E(C,M,U)2T30NA CMPEV050 13.50 11.50 28,600 21,500 1000
3/4
3/8
3/4
3/8 3/4 3/8 .070 A2TXV01
E(C,M,U)1P30NA E(C,M,U)2T30NA CMPEV075 13.50 11.50 28,600 21,500 1000
3/4
3/8
3/4
3/8 3/4 3/8 .070 A2TXV01
E(C,M,U)1P30NA E(C,M,U)2T30NA MPGAV050 14.00 12.00 28,600 21,500 1000
3/4
3/8
3/4
3/8 3/4 3/8 .070 A2TXV01
E(C,M,U)1P30NA E(C,M,U)2T30NA MPGAV075 14.00 12.00 28,600 21,500 1000
3/4
3/8
3/4
3/8 3/4 3/8 .070 A2TXV01
E(C,M,U)1P30NB E(C,M,U)2T30NB CMPEV050 14.00 11.50 28,600 21,500 1000
3/4
3/8
3/4
3/8 3/4 3/8 .070 A2TXV01
E(C,M,U)1P30NB E(C,M,U)2T30NB MPGAV075 14.00 11.50 28,600 21,500 1000
3/4
3/8
3/4
3/8 3/4 3/8 .070 A2TXV01
E(C,M,U)1P36NA E(C,M,U)2T36NA CMPEV050 13.50 12.00 29,400 22,100 1000
3/4
3/8
3/4
3/8 3/4 3/8 .070 A2TXV01
E(C,M,U)1P36NA E(C,M,U)2T36NA CMPEV075 13.50 12.00 29,400 22,100 1000
3/4
3/8
3/4
3/8 3/4 3/8 .070 A2TXV01
E(C,M,U)1P36NA E(C,M,U)2T36NA MPGAV050 14.00 12.00 29,400 22,100 1000
3/4
3/8
3/4
3/8 3/4 3/8 .070 A2TXV01
E(C,M,U)1P36NA E(C,M,U)2T36NA MPGAV075 14.00 12.00
29,400 22,100 1000
3/4
3/8
3/4
3/8 3/4 3/8 .070 A2TXV01
E(C
,H,M,U)1P36NB E(C,H,M,U)2T36NB CMPEV0100 14.00 12.00 29,400 22,100 1000
3/4
3/8
3/4
3/8 3/4 3/8 .070 A2TXV01
E(C,H,M,U)1P36NB E(C,H,M,U)2T36NB MPGAV0100 14.00 12.00 29,400 22,100 1000
3/4
3/8
3/4
3/8 3/4 3/8 .070 A2TXV01
Outdoor
Model
2AC13**30P
1
Certified in accordance with Unitary Air Conditioner Certification Program, which is based on ARI Standard 210/240.
2
Required to achieve ARI rating.
A blower time delay is required to achieve ARI rating.