Ducane (HVAC) 2AC13 Air Conditioner User Manual


 
2AC13SplitSystemAirConditioner
13
CoolingPerformancewithAirHandlersandFurnaces(18)
Indoor Model
Variable
Speed
Furnace
SEER EER
Rated
ARI
Capacity
1
Rated
Sensible
Capacity
CFM
Refrigerant
Connection
Refrigerant
Line Size
Indoor
Metering
Device
Piston or Field
Installed TXV
Factory
Installed TXV
Outdoor Indoor
Suction
Liquid
Req'd
Indoor
2
Orifice
Optional
Field
Installed
Orifice
Suction
Liquid
Suction
Liquid
RBCS2M18C****P RBCS2M18C****T --- 13.00 12.00 17,900 12,900 600
3/4
3/8
3/4
3/8 3/4 3/8 .053 A2TXV01
RBCS2M24V****P --- --- 14.00 12.50 18,000 13,000 550
3/4
3/8
3/4
3/8 3/4 3/8 .053 A2TXV01
E(C,M,U)1P18NA E(C,M,U)2T18NA CMPEV050 14.00 12.00 17,300 12,500 600
3/4
3/8
3/4
3/8 3/4 3/8 .053 A2TXV01
E(C,M,U)1P18NA E(C,M,U)2T18NA CMPEV075 14.00 12.00 17,300 12,500 600
3/4
3/8
3/4
3/8 3/4 3/8 .053 A2TXV01
E(C,M,U)1P18NA E(C,M,U)2T18NA MPGAV050 14.00 12.00 17,300 12,500 600
3/4
3/8
3/4
3/8 3/4 3/8 .053 A2TXV01
E(C,M,U)1P18NA E(C,M,U)2T18NA MPGAV075 14.00 12.00 17,300 12,500 600
3/4
3/8
3/4
3/8 3/4 3/8 .053 A2TXV01
E(C,M,U)1P19NA E(C,M,U)2T19NA CMPEV050 14.00 12.50 17,300 12,500 600
3/4
3/8
3/4
3/8 3/4 3/8 .053 A2TXV01
E(C,M,U)1P19NA E(C,M,U)2T19NA CMEV075 14.00 12.50 17,300 12,500 600
3/4
3/8
3/4
3/8 3/4 3/8 .053 A2TXV01
E(C,M,U)1P19NA E(C,M,U)2T19NA MPGAV050 14.00 12.50 17,300 12,500 600
3/4
3/8
3/4
3/8 3/4 3/8 .053 A2TXV01
E(C,H,M,U)1P19NA E(C,H,M,U)2T19A MPGAV075 14.00 12.50 17,300 12,500 600
3/4
3/8
3/4
3/8 3/4 3/8 .053 A2TXV01
E(C,H,M,U)1P23NA E(C,H,M,U)2T23NA CMPEV050 14.00 12.50 17,300 12,500 600
3/4
3/8
3/4
3/8 3/4 3/8 .053 A2TXV01
E(C,H,M,U)1P23NA E(C,H,M,U)2T23NA CMPEV075 14.00 12.50 17,300 12,500 600
3/4
3/8
3/4
3/8 3/4 3/8 .053 A2TXV01
E(C,H,M,U)1P23NA E(C,H,M,U)2T23NA MPGAV050 14.00 12.50 17,300 12,500 600
3/4
3/8
3/4
3/8 3/4 3/8 .053 A2TXV01
E(C,H,M,U)1P23NA E(C,H,M,U)2T23NA MPGAV075 14.00 12.50 17,300 12,500 600
3/4
3/8
3/4
3/8 3/4 3/8 .053 A2TXV01
E(C,M,U)1P24NA E(C,M,U)2T24NA CMPEV050 14.00 12.50 17,300 12,500 600
3/4
3/8
3/4
3/8 3/4 3/8 .053 A2TXV01
E(C,M,U)1P24NA E(C,M,U)2T24NA CMPEV075 14.00 12.50 17,300 12,500 600
3/4
3/8
3/4
3/8 3/4 3/8 .053 A2TXV01
E(C,M,U)1P24NA E(C,M,U)2T24NA MPGAV050 14.00 12.50 17,300 12,500 600
3/4
3/8
3/4
3/8 3/4 3/8 .053 A2TXV01
E(C,M,U)1P24NA E(C,M,U)2T24NA MPGAV075 14.00 12.50 17,300 12,500 600
3/4
3/8
3/4
3/8 3/4 3/8 .053 A2TXV01
Outdoor
Model
2AC13**18P
** = B, L, BC, LC
* = B, L
1
Certified in accordance with Unitary Air Conditioner Certification Program, which is based on ARI Standard 210/240.
2
Required to achieve ARI rating.
A blower time delay is required to achieve ARI rating.