Ducane (HVAC) 2AC13 Air Conditioner User Manual


 
2AC13SplitSystemAirConditioner
13
** = B, L, BC, LC
* = B, L
CoolingPerformancewithEvaporatorCoils
Outdoor
Model
Indoor Model
SEER EER
Rated
ARI
Capacity
1
Rated
Sensible
Capacity
CFM
Refrigerant
Connection
Refrigerant
Line Size
Indoor
Metering
Device
Piston or Field
Installed TXV
Factory
Installed TXV
Outdoor Indoor
Suction
Liquid
Req'd
Indoor
2
Orifice
Optional
Field
Installed
Orifice
Suction
Liquid
Suction
Liquid
E(C,M,U)1P18N(A,B) E(C,M,U)2T18N(A,B) 13.00 11.00 17,000 12,200 550
3/4
3/8
3/4
3/8 3/4 3/8 .053 A2TXV01
E(C,M,U)1P19NA E(C,M,U)2T19NA 13.00 11.50 17,000 12,200 550
3/4
3/8
3/4
3/8 3/4 3/8 .053 A2TXV01
E(C,H,M,U)1P23N(A,B) E(C,H,M,U)2T23N(A,B) 13.00 11.50 17,000 12,200 550
3/4
3/8
3/4
3/8 3/4 3/8 .053 A2TXV01
E(C,M,U)1P24N(A,B) E(C,M,U)2T24N(A,B) 13.00 11.50 17,000 12,200 550
3/4
3/8
3/4
3/8 3/4 3/8 .053 A2TXV01
E(C,M,U)1P19NA E(C,M,U)2T19NA 13.00 11.00 22,800 17,100 750
3/4
3/8
3/4
3/8 3/4 3/8 .062 A2TXV01
E(C,H,M,U)1P23N(A,B) E(C,H,M,U)2T23N(A,B) 13.00 11.00 23,200 17,400 750
3/4
3/8
3/4
3/8 3/4 3/8 .062 A2TXV01
E(C,M,U)1P24N(A,B) E(C,M,U)2T24N(A,B) 13.00 11.00 23,000 17,300 750
3/4
3/8
3/4
3/8 3/4 3/8 .062 A2TXV01
E(C,H,M,U)1P29NA E(C,H,M,U)2T29NA 13.00 11.50 23,000 17,300 750
3/4
3/8
3/4
3/8 3/4 3/8 .062 A2TXV01
E(C,H,M,U)1P23N(A,B) E(C,H,M,U)2T23N(A,B) 13.00 11.00 27,800 20,900 900
3/4
3/8
3/4
3/8 3/4 3/8 .070 A2TXV01
E(C,H,M,U)1P29NA E(C,H,M,U)2T29NA 13.00 11.00 28,600 21,500 900
3/4
3/8
3/4
3/8 3/4 3/8 .070 A2TXV01
E(C,M,U)1P30N(A,B,C) E(C,M,U)2T30N(A,B,C) 13.00 11.00 28,200 21,200 900
3/4
3/8
3/4
3/8 3/4 3/8 .070 A2TXV01
E(C,H,M,U)1P36N(A,B,C) E(C,H,M,U)2T36N(A,B,C) 13.00 11.00 29,000 21,800 900
3/4
3/8
3/4
3/8 3/4 3/8 .070 A2TXV01
E(C,H,M,U)1P29NA E(C,H,M,U)2T29NA 13.00 10.50 34,600 26,600 1060
3/4
3/8
3/4
3/8 3/4 3/8 .076 A2TXV01
E(C,H,M,U)1P36N(A,B,C) E(C,H,M,U)2T36N(A,B,C) 13.00 11.00 34,600 26,600 1060
3/4
3/8
3/4
3/8 3/4 3/8 .076 A2TXV01
E(C,H,M,U)1P43NB E(C,H,M,U)2T43NBC 13.00 11.00 35,200 27,100 1060
3/4
3/8
7/8
3/8 7/8 3/8 .076 A2TXV01
E(C,H,M,U)1P43NB E(C,H,M,U)2T43NB 13.00 11.50 40,000 28,000 1250
7/8
3/8
7/8
3/8 7/8 3/8 .080 A2TXV02
E(C,M,U)1P48N(B,C) E(C,M,U)2T48N(B,C) 13.00 11.00 39,000 27,200 1250
7/8
3/8
7/8
3/8 7/8 3/8 .080 A2TXV02
E(C,H,U)1P49NC E(C,H,U)2T49NC 13.00 11.00 40,000 28.000 1250
7/8
3/8
7/8
3/8 7/8 3/8 .080 A2TXV02
E(C,H,M,U)1P43NB E(C,H,M,U)2T43NB 13.00 11.50 45,000 32,000 1600
7/8
3/8
7/8
3/8 7/8 3/8 .088 A2TXV02
E(C,M,U)1P48N(B,C) E(C,M,U)2T48N(B,C) 13.00 12.00 45,000 32,000 1600
7/8
3/8
7/8
3/8 7/8 3/8 .088 A2TXV02
E(C,H,U)1P49NC E(C,H,U)2T49NC 13.00 11.50 46,000 32,600 1600
7/8
3/8
7/8
3/8 7/8 3/8 .088 A2TXV02
E(C,M,U)1P50NC E(C,M,U)2T50NC 13.00 11.50 45,000 32,000 1600
7/8
3/8
7/8
3/8 7/8 3/8 .088 A2TXV02
E(C,U)1P60ND E(C,U)2T60ND 13.00 11.50 45,000 32,000 1600
7/8
3/8
7/8
3/8 7/8 3/8
.088 A2TXV02
E(C
,H,U)1P62NC E(C,H,U)2T62NC 13.00 12.00 45,500 32,300 1600
7/8
3/8
7/8
3/8 7/8 3/8 .088 A2TXV02
E(C,H,U)1P62ND E(C,H,U)2T62ND 13.00 12.00 45,500 32,300 1600
7/8
3/8
7/8
3/8 7/8 3/8 .088 A2TXV02
E(C,H,U)1P49NC E(C,H,U)2T49NC 13.00 11.00 53,000 38,600 1800
7/8
3/8
7/8
3/8 1-1/8 3/8 .098 A2TXV02
EH1P49ND --- 13.00 11.00 53,000 38,600 1800
7/8
3/8
7/8
3/8 1-1/8 3/8 .098 A2TXV02
E(C,H,U)1P62NC E(C,H,U)2T62NC 13.00 11.50 54,000 39,400 1800
7/8
3/8
7/8
3/8 1-1/8 3/8 .098 A2TXV02
E(C,H,U)1P62ND E(C,H,U)2T62ND 13.00 11.00 53,000 38,600 1800
7/8
3/8
7/8
3/8 1-1/8 3/8 .098 A2TXV02
2AC13**18P
2AC13**24P
2AC13**30P
2AC13**36P
2AC13*42P
2AC13*48P
2AC13*60P
1
Certified in accordance with Unitary Air Conditioner Certification Program, which is based on ARI Standard 210/240.
2
Required to achieve ARI rating.
A blower time delay is required to achieve ARI rating.