[310]-[311] Partition Identifier Codes
Enter a 6 digit Maintenance Code
[350] – Communicator Format Options
This section determines the communication format used for central
station reporting. From the chart listed below program the 2-digit num-
ber for the desired format for the first and second telephone number
[367] – Opening/Closing Call Direction Options
The first toggle option in this section is used to enable/disable opening/
closing reporting for partition 1. To enable opening/closing reporting
turn option [1] ON. Configure the options as required and press [#] to
exit
.
[377] Communication Variables
NOTE: For UL Installations, the Entry Delay plus the Communications
Delay must not exceed 60 seconds.
[380] – First Communicator Option Codes
[381] – Second Communicator Option Codes
The 3rd toggle option in this section is used to enable/disable auto-
matic SIA reporting. The 5th toggle option is used to enable/disable
automatic Contact ID reporting. Configure the options as required and
press [#] to exit.
NOTE:If the automatic SIA or automatic Contact ID reporting formats
are not used, reporting codes must be programmed. To program
reporting codes refer to the PowerSeries PC1616/1832/1864 Refer-
ence Manual which can be downloaded from the DSC web site at
www.dsc.com
[382] – Third Communicator Option Codes
The 4th toggle option in this section is used to enable/disable Call
Waiting Cancel. Configure the options as required and press [#] to exit.
NOTE:A Call Waiting Cancel on a Non Call Waiting line will prevent
successful connection to the central station.
[701] – First International Options Codes
Option 7 in this section Selects Battery Charge Options.
Select ON for 7 Ahr and 14 Ahr batteries (700 mA charge rate)
Select OFF for Standard 4 Ahr batteries (400 mA charge rate)
[310 System Acct. Code I___II___II___II___II___II___I
[311] Partition 1 Acct. Code I___II___II___II___I
Def Enter 2 digits
From Chart Below
04
04
I___II___I
I___II___I
NOTE:
3rd Phone Number follows the format of the
1st Phone Number
01 20BPS, 1400 Hz Handshake
02 20BPS, 2300 Hz Handshake
03 DTMF Contact ID
04 SIA FSK
05 Pager
06 Residential Dial
07 10BPS, 1400 Hz Handshake
08 10BPS, 2300 Hz Handshake
09 Private Line
10 Scantronics 4-8-1 Fast Slo
12 Robofon
13 CESA 200
Opt Default Description
1 I__I ON 1st Telephone Number
OFF Disabled
2 I__I ON 2nd Telephone Number
OFF Disabled
5 I__I ON Alternate Communicator
OFF Disabled
Def Enter 3 digits
as indicated below
003 I___II___II___I
003 I___II___II___I
003 I___II___II___I
000 I___II___II___I
030 I___II___II___I
010 I___II___II___I
030 I___II___II___I
030 I___II___II___I
007 I___II___II___I
030 I___II___II___I
000 I___II___II___I
Swinger Shutdown
(Alarms and Rest.
Swinger Shutdown
(Tamper and Rest.
Swinger Shutdown
(Maint. and Rest.
Communication Delay
AC Failure Comm Delay
TLM Trouble Delay
Test Transmission Cycle
(land line)
Not Used
Zone low Battery
Transmission Delay
Delinquency Transmis-
sion Cycle
Communications
Cancelled Window
(001-014 Transmissions)
(001-014 Transmissions,
000=disabled)
(001-014 Transmissions,
000=disabled)
(000-255 seconds)
(001-255 minutes)
No. of checks req’d (003-
255)
(001-255 days/minutes)
(000-255 days)
(000-255 days/hours)
(000-255 minutes)
NOTE:
Option 1 is defaulted to
001
for CP-01 Installations
Option 4 is defaulted to
030
for CP-01 Installations
Option 11 is defaulted to
005
for CP-01 Installations
Opt Default Description
1 I__I ON Communications Enabled
OFF Communications Disabled
2 I__I ON Restorals on Bell Time-out
OFF Restorals Follow Zones
3 I__I ON Pulse Dialing
OFF DTMF Dialing
5 I__I ON 3rd Telephone Number Enabled
OFF 3rd Telephone Number Disabled
8 I__I ON Delinquency Follows Zone Activity (Hours)
OFF Delinquency Follows Arming (Days)
Opt Default Description
3 I__I ON SIA Sends Programmed Reporting Codes
OFF SIA Sends Automatic Reporting Codes
5 I__I ON Contact ID Uses Programmed Reporting
Codes
OFF Contact ID Uses Automatic Reporting Codes
Opt Default Description
4 I__I ON Call Waiting Cancel Enabled
OFF Call Waiting Cancel Disabled
5 I__I ON T-Link Interface Enabled
OFF T-Link Interface Disabled
Opt Default Description
7 I__I ON High Current Battery Charge (700mA)
OFF Standard Battery Charge Rate (400mA)