DSC dsc power series security systems Home Security System User Manual


 
[402] Downloading Computer Phone Number (32-digits)
[403] Downloading Access Code
Enter 4 or 6-digit code
This code identifies the downloading computer to the panel.
The downloading access code prevents unauthorized access to the panel.
This code must match the code programmed in the downloading file before the
panel will allow remote or local DLS connection. Enter a new downloading
access code to disable downloading.
[404] Panel Identification Code
This code identifies the panel to the downloading computer.
See section [403]
Enter 6 decimal places
[499][Installer Code][499] Initiate PC-Link
Enter [499][Installer Code][499]
Special Installer Functions
[000] Keypad Programming
Note: This programming must be done at each keypad
[001]-[004] Zone Definitions
Enter the number corresponding to the zone definitions required.The keypad
will beep rapidly 3 times and move to the next step. If an invalid number is
entered the keypad will revert to the default setting (option [1]).
Press [#] to exit the section.
I
D
II___II___II___II___II___II___II___II___II___II___II___II___II___II___II___I
I___II___II___II___II___II___II___II___II___II___II___II___II___II___II___II___I
Default
XXXX
XX I___II___II___II___II___II___I
Default
XXXXXX
I___II___II___II___II___II___I
Enter section# for the following features
[900]
[902]
[903]
[904]
Panel Version ([][8][Installer Code][900])
Module Supervision Reset ([][8][Installer Code][902])
Module Supervision Field ([][8][Installer Code][903])
Wireless Module Placement Test ([][8][Installer Code][904])
Enter section#, Installer Code section# for the following features
[990] INSTALLER CODE [990]
[991] INSTALLER CODE [991]
[993] INSTALLER CODE [993]
[995] INSTALLER CODE [995]
[996] INSTALLER CODE [996]
[997] INSTALLER CODE [997]
[999] INSTALLER CODE [999]
Installer Lockout Enable
Installer Lockout Disable
Restore Alt.Comm. Factory Defaults
Restore Escort 5580 Factory Defaults
Restore PC5132 Factory Defaults
Restore PC5400 Factory Defaults
Restore Panel Factory Defaults
[0]
[1]
[2]
[3]
[4]
[5]
Slot Address (0-8) for partition, 1-8 for slot
Function key Assignment (00-32)
Function key Assignment (00-32)
Function key Assignment (00-32)
Function key Assignment (00-32)
Function key Assignment (00-32)
Slot Address
Key
1
Key
2
Key
3
Key
4
Key
5
LCD5501Z
LED
Defaults
11 03 04 06 14 16
LCD5500Z
Defaults
18 03 04 06 14 16
Keypad 1
Keypad 2
Keypad 3
Keypad 4
Keypad 5
Keypad 6
Keypad 7
Keypad 8
KEYPAD FUNCTION KEY DEFINITIONS
00 Null Key (Key not used)
01 Partition 1 Select
02 Partition 2 Select
03 Stay Arm
04 Away Arm
05 [][9] No entry arm
06 [][4] Chime On/Off
07 [][6][----][4]System Test
08 [][1] Bypass Mode
09 [][2] Trouble display
10 [][3] Alarm memory
11 [][5] User programming
12 [][6] User functions
13 Command output 1 [71]
14 Command output 1 [72] Sensor
Reset
15 General voice prompted help
16 [][0] Quick Exit
17 [][0] Activate Stay/Away
18 Identified voice prompted
help
19 Command output 3 [73]
20 Not used
21 Command output 4 [74]
22 Active camera monitor
selection
23 Bypass Recall
24 Bypass Group Recall
25 Not Used
26 Time Programming
27 Partition 3 Select
28 Partition 4 Select
29 Partition 5 Select
30 Partition 6 Select
31 Partition 7 Select
32 Partition 8 Select
[001] Zone 1-16 Definitions
ALL Models
00 Null Zone (not used)
01 Delay 1
02 Delay 2
03 Instant
04 Interior
05 Interior, Stay/Away
06 Delay, Stay/Away
07 Delayed 24-hr Fire
(Hard-wired)
08 Standard 24-hr Fire
(Hard-wired)
09 24-hr Supervisory
10 24-hr Supervisory Bu
11 24-hr Burglary
12 24-hr Holdup
13 24-hr Gas
14 24-hr Heat
15 24-hr Medical
16 24-hr Panic
17 24-hr Emergency
18 24-hr Sprinkler
19 24-hr Water
20 24-hr Freeze
21 24-hr Latching
Tamper
22 Momentary Keyswitch
arm
23 Maintained Key-
switch Arm
24 Future Use
25 Interior Delay
26 25-hr non-alarm
27 Delayed 24-hr Water
Flow
28 Instant 24-hr Water
Flow
29 Auto-verified Fire
30 Fire Supervisory
31 Day zone
32 24-hr Bell/Buzzer
33 Push to set
34 Final Door set
35 Instant Stay, Away
36 24-hr Non latching
Tamper
37 Night Zone
87 Delayed 24-hr Fire
(Wireless)
88 24-hr Fire (Wireless)
Def
Def
01
I__II__I Zone 1
03
I__II__I Zone 2
03
I__II__I Zone 3
03
I__II__I Zone 4
04
I__II__I Zone 5
04
I__II__I Zone 6
04
I__II__I Zone 7
04
I__II__I Zone 8
00
I__II__I Zone 9
00
I__II__I Zone 10
00
I__II__I Zone 11
00
I__II__I Zone 12
00
I__II__I Zone 13
00
I__II__I Zone 14
00
I__II__I Zone 15
00
I__II__I Zone 16
[002] Zone 17-32 Definitions
PC1864
&
PC1832
Def
Def
00
I__II__I Zone 17
00
I__II__I Zone 18
00
I__II__I Zone 19
00
I__II__I Zone 20
00
I__II__I Zone 21
00
I__II__I Zone 22
00
I__II__I Zone 23
00
I__II__I Zone 24
00
I__II__I Zone 25
00
I__II__I Zone 26
00
I__II__I Zone 27
00
I__II__I Zone 28
00
I__II__I Zone 29
00
I__II__I Zone 30
00
I__II__I Zone 31
00
I__II__I Zone 32
[003] Zone 33-48 Definitions
PC1864
Only
Def
Def
00
I__II__I Zone 33
00
I__II__I Zone 34
00
I__II__I Zone 35
00
I__II__I Zone 36
00
I__II__I Zone 37
00
I__II__I Zone 38
00
I__II__I Zone 39
00
I__II__I Zone 40
00
I__II__I Zone 41
00
I__II__I Zone 42
00
I__II__I Zone 43
00
I__II__I Zone 44
00
I__II__I Zone 45
00
I__II__I Zone 46
00
I__II__I Zone 47
00
I__II__I Zone 48
[004] Zone 49-64 Definitions
PC1864
Only
Def
Def
00
I__II__I Zone 49
00
I__II__I Zone 50
00
I__II__I Zone 51
00
I__II__I Zone 52
00
I__II__I Zone 53
00
I__II__I Zone 54
00
I__II__I Zone 55
00
I__II__I Zone 56
00
I__II__I Zone 57
00
I__II__I Zone 58
00
I__II__I Zone 59
00
I__II__I Zone 60
00
I__II__I Zone 61
00
I__II__I Zone 62
00
I__II__I Zone 63
00
I__II__I Zone 64
WWW.DIYALARMFORUM.COM