INSTALLATION INSTRUCTIONS
LOCATING THE STOVE
• Install the stove as close to the chimney as possible.
• Many configuration are possible, the most frequent are illustrated in figures 1,2 and 3.
• Respect clearances indicated on page 1. They have been tested according to approvals.
• Always respect clearances of stove pipe manufacturers. Larger clearances always prevail.
Figure 1 : CORNER INSTALLATION
Figure 2 : PARRALLÈL INSTALLATION
Figure 3 : WALL INSTALLATION
Table 1 : CLEARANCES TO COMBUSTIBLES
mm in
Back 150 6
Side 150 6
Corners 150 6
Top 915 36
Flue Pipe 230 9
• IMPORTANT: It is essential to ensure that the room were the stove is located is sufficiently
ventilated to provide an adequate air supply.
• It is possible that if your home is well insulated, that you will have to install an outside fresh air
intake.
THE BURNING OF ONE LITRE OF FUEL (OIL) REQUIRES APPROXIMATELY 30 M
3
OF AIR AND
WILL PRODUCE ABOUT 0.8 KG OF WATER OF WATER VAPOR AND 9 M
3
OF CARBONE
DIOXIDE AND ATMOSPHERIC NITROGEN. A SOURCE OF AIR FROM THE OUTSIDE IS NEEDED
TO REPLACE COMBUSTION AIR. Ref : standard B-139 4.1.4