TROUBLESHOOTING GUIDE
PROBLEMS
CAUSES
SOLUTION
ON POSITION 6 (MAXIMUM)
THE FLAME IS LONG AND
SMOKY, THERE IS SUIT
BUILD UPON THE GLASS
Position 6 was reached too
quickly.
1. Set flow regulating handle
to position 1.
2. wait for combustion to
stabilize.
3. Progressively increase flow
to desired position.
NOTE : SEE LIGHTING
PROCEDURES.
Maximum flow is too high 1. Set flow to a lower position
2. Call a qualified technician
to adjust the valve.
ON POSITION 1 (MINIMUM)
THE FLAME PRODUCES
SMOKE AND SUITS THE
GLASS
Cleaning tee and/or burner are
dirty
1. Activate cleaning tee
according to procedures
2. Schedule at the next shut
off to clean the burner.
Orifice of plunger is partially
plugged.
1. Progressively increase flow
to position 6.
2. Push in manual
consecutive times on the
thermostatique regulator
bottom to remove dirt form
the orifice.
NOTE : If the problem persist,
you may have to remove and
clean out the valve with alcohol.
Call your specialized
technician.
ON POSITION 1 (MINIMUM)
THE FLAME PRODUCES
SMOKE AND SUITS THE
GLASS
Flow is to low 1. Slightly increase the flow
regulating handle.
2. Call a specialized
technician.
Page 11 of 15