Dometic CA1000 Air Conditioner User Manual


 
Disposal Dometic CA1000
34
8Disposal
Place the packaging material in the appropriate recycling waste bins
wherever possible.
9 Troubleshooting
Possible malfunction Cause Remedies
Error message F02:
The system does not
switch on and the display
shows an error mes-
sage.
The temperature sensor is not cor-
rectly connected.
Switch off the system
Switch it on again after 10 min-
utes
If the fault occurs again, contact
an authorised workshop.
Error message F04:
The condensation water
that has formed is not
being discharged, and
an error message
appears in the display.
The pump is clogged or defec-
tive.
The condensation water hose is
clogged.
The float switch is defective or
jammed.
Contact an authorised workshop.
_IA_CA1000.book Seite 34 Freitag, 30. Januar 2009 11:12 11