The event display you'll see at the keypad is slightly different for each
event type.
Using the Display Events Function
1. Access the User Menu.
2. Press the COMMAND key until DISPLAY EVENTS? displays.
Press any SELECT key.
3. The keypad displays the oldest recorded event.
Use the COMMAND key to scroll down through the list of events. Use
the ARROW key to scroll back up through the event displays. If you
press the ARROW key when you first enter the Display Events, the
keypad returns to the Status List.
Zone Bypass Event Displays
This displays the bypassing of system zones.
Display Description
JONES RESIDENCE Zone 6 bypassed by user 12. Press the
6 BYPS 12 SELECT key under the zone number to
display the custom zone name
programmed into the system.
Bypass Event Types - There are 2 event types:
BYP - Bypass RST - Restore
Note: You may sometimes see the user as SWG. This is short for the
Swinger Bypass feature that allows the system to automatically
bypass a zone that faults more than 3 times while the system is
armed. Your system may or may not have this feature.
A B C D E F G H I
J KL
V W XMN O P Q R S T U
Y
Z
COMMAND
90
1234
56
7
8
POWER
JONES RESIDENCE
FRI 2: 51 AM
ARMED
Display Events
User Code Level: Master or Standard.
Function: Allows you to review up to 16 past events that occurred on
your system from any keypad. Once 16 events are stored, any new
event causes the oldest event to be cleared.
When accessed, the Display Events
option displays events recorded
automatically by the system in the order
of their occurrence. You can view the
events starting from the oldest to the
most recent.
While in Display Events, you can use
the COMMAND and ARROW keys to
go forward or backward through the list of recorded events. There are
five event types recorded by the system:
Zone Events - Records zone alarms, troubles, and restores to
normal condition.
Zone Bypass Events - Records the bypassing of any zone. The
zone number, zone name, and the user number of the person
bypassing the zone is recorded.
Arming and Disarming - Records arming and disarming of the
system by user number and the areas armed or disarmed.
User Code Changes - Records addition, deletion, and change of
user codes. Also notes user number of person making the change.
System Monitors - Records any loss of AC power or low battery
conditions on the system.
User Menu
COMMANDARROW