Dimplex S1 7KS Heat Pump User Manual


 
12
APPENDIX: 12.2 EQUIPMENT DATA
Equipment Data
EQUIPMENT DATA for Brine-to-Water Heat Pumps for Heating
1
TYPE AND COMMERCIAL DESCRIPTION ..7KS ..9KS ..11KS ..14KS
2
MODEL
2.1 Type compact compact compact compact
2.2 Enclosure type acc. to EN 60 529 IP 20 IP 20 IP 20 IP 20
2.3 Installation site indoors indoors indoors indoors
3
PERFORMANCE DATA
3.1 Operating temperature limits:
Heating water supply °C max. 55 max. 55 max. 55 max. 55
Brine (heat source) °C -5 to +25 -5 to +25 -5 to +25 -5 to +25
Antifreeze agent
monoethylene glycol monoethylene glycol monoethylene glycol monoethylene glycol
Minimum brine concentration (-13°C freezing temperature)
25% 25% 25% 25%
3.2 Heating water temperature difference at B0 / W35
K 9,9 10,5 10,1 9,6
3.3 Heating capacity / coeff.of perform. at B-5 / W55
1)
kW / --- 5,6 / 2,2 7,7 / 2,3 9,4 / 2,4 12,5 / 2,6
at B0 / W50
1)
kW / --- 6,7 / 2,9 9,0 / 3,1 11,3 / 3,0 14,2 / 3,4
at B0 / W35
1)
kW / --- 6,9 / 4,3 9,2 / 4,4 11,8 / 4,4 14,5 / 4,5
3.4 Sound power level dB(A) 51 51 51 51
3.5 Heating water flow rate at internal pressure difference m³/h / Pa 0,6 / 2500 0,75 / 4500 1,0 / 3500 1,3 / 3500
3.6 Free presssure, heating circulating pump (stage 3) Pa 47500 43500 65500 64500
3.7 Brine flow rate at internal pressure difference (heat source) m³/h / Pa 1,7 / 10000 2,3 / 16000 3,0 / 13000 3,5 / 13000
3.8 Free pressure, brine pump (stage 3) Pa 55000 44000 40000 34000
3.9 Refrigerant; total charge weight type / kg R407C / 1,5 R407C / 1,8 R407C / 2,0 R407C / 2,3
4
DIMENSIONS, CONNECTIONS AND WEIGHT
4.1 Equipment dimensions without connections
4)
H x W x L mm
1110 × 652 × 653 1110 × 652 × 653 1110 × 652 × 653 1110 × 652 × 653
4.2 Equipment connections for heating system inches R 1¼" ext.
R 1¼" ext. R 1¼" ext. R 1¼" ext.
4.3 Equipment connections for heat source inches R 1¼" ext. R 1¼" ext. R 1¼" ext. R 1¼" ext.
4.4 Weight of transport unit(s) incl. packaging kg 179 180 191 203
5
ELECTRICAL CONNECTION
5.1 Nominal voltage; fusing V / A 400 / 16 400 / 16 400 / 16 400 / 16
5.2 Nominal power consumption
1)
B0 W35 kW 1,6 2,07 2,66 3,22
5.3 Starting current with soft starter A 30 (no soft starter) 15 26 26
5.4
Nominal current B0 W35 / cosϕ
A / --- 2,89 3,77 4,84 5,81
6
COMPLIES WITH EUROPEAN SAFETY REGULATIONS
3) 3) 3) 3)
7
OTHER DESIGN CHARACTERISTICS
7.1 Water inside equipment protected against freezing
2)
yes yes yes yes
7.2 Performance settings 1 1 1 1
7.3 Controller internal / external internal internal internal internal
1)
2) The heating circulating pump and the controller of the heat pump must be ready for operation at all times.
3) s. EC Declaration of Conformity
4) Please keep in mind that more space is required for pipe connection, operation and maintenanc.
Subject to technical modifications
Issued: 23.04.2004
These data characterize the size and performance capability of the system. For economic and energetic reasons, additional
factors such as balance point and control need to be taken into consideration. Abbreviations have the following meaning, e.g. B10 /
W55: heat source temperature 10 °C and heating water supply temperature 55 °C.