Dimplex Indoor Electric Fireplace Indoor Fireplace User Manual


 
MAINTENANCE
WARNING
Disconnect power before attempting any maintenance or cleaning to reduce the risk of fire,
electric shock or damage to persons.
LIGHT BULB REPLACEMENT
Allow at least 5 minutes for light bulbs to cool before touching bulbs to avoid accidental burning
of skin.
Light bulbs need to be replaced when you notice a dark section of the flame or when the clarity
and detail of the log exterior disappears. There are two bulbs under the log set which generate
the flames and embers.
TOOL REQUIREMENTS
Phillips screw driver
HELPFUL HINTS
It is a good idea to replace all light bulbs at one time if they are close to the end of their rated
life. Group replacement will reduce the number of times you need to open the unit to replace
light bulbs.
LIGHT BULB REQUIREMENTS
Two (2) clear chandelier or candelabra bulbs
with an E-12 (small) socket base, 60 watt rating.
BULB REPLACEMENT
1. Unplug the unit from the outlet.
2. For EWMC-CC-SS
a. Unsnap the front door from the unit.
b. Remove the lower moulding from
the unit.
c. Lift up, and remove the unit from
the wall. Set the unit down on it’s
right side.
3. Remove the rear door from the left side of the unit
by unfastening one phillips screw. Set the
door and screw aside.
4. Reach inside opening to remove the bulb(s).
remove the nearest bulb before attempting
to remove the further bulb. Bulbs are unscrewed in
counter-clockwise direction.
5. Insert new bulb(s).
6. Assemble in reverse order and re-hang on the wall.
7. Plug in the corner wall mounted electric fireplace.
FIGURE 14
13