Dimplex LA 9PS Heat Pump User Manual


 
E-9
English
11
11 Device Information
Device information for air-to-water heat pumps for heating purposes
1 Type and order code
LA 9PS LA 12PS LA 18PS
2Design
2.1 Degree of protection according to EN 60 529 for compact devices and heating
components
IP24 IP24 IP24
2.2 Installation Location Outdoors Outdoors Outdoors
3 Performance data
3.1 Operating temperature limits:
Heating water flow/return flow
1
°C / °C
1. See operating limits diagram
Up to 65 / above 18 Up to 65 / above 18 Up to 65 / above 18
Air °C -20 to +35 -20 to +35 -20 to +35
3.2 Temperature spread of heating water at A2 / W35 K 5.5 6.3 8.2
Heat output / COP at A-7 / W35
2
kW / ---
2. This data indicates the size and capacity of the system. For an analysis of the economic and energy efficiency of the system, other parameters, such as, in particular, the defrosting
capacity, the bivalence point and regulation, should also be taken into consideration. The specified values, e.g. A2 / W55, have the following meaning: 2 °C external air temperature
and 55 °C heating water flow temperature.
5.6 / 2.6 7.2 / 2.6 10.6 / 2.4
at A-7 / W50
2
kW / ---
5.0 / 2.2 6.4 / 2.0 10.3 / 2.0
at A2 / W35
2
kW / ---
7.1 / 3.2 9.4 / 3.2 14.1 / 3.0
at A7 / W35
2
kW / ---
8.5 / 3.6 11.1 / 3.8 15.8 / 3.3
at A10 / W35
2
kW / ---
9.6 / 4.0 12.1 / 4.0 18.3 / 3.7
3.3 Sound power level dB(A) 62 65 74
3.4 Heating water flow with an internal pressure differential of m³/h / Pa 1.2 / 9000 1.4 / 9000 1.6 / 9000
3.5 Air flow rate m³/h / Pa 2000 2000 4000
3.6 Refrigerant; total filling weight type / kg R290 / 1.0 R290 / 1.4 R290 / 2.0
4 Dimensions, connections and weight
4.1 Device dimensions H x W x L cm 132 x 77 x 66 113 x 80 x 159 113 x 80 x 199
4.2 Device connections to heating system Inch G 1'' external G 1'' external G 1'' external
4.3 Weight of the transportable unit(s) incl. packing kg 168 235 254
5 Electrical Connection
5.1 Nominal voltage; fuse protection V / A 400 / 16 400 / 16 400 / 20
5.2 Nominal power consumption
2
A2 W35 kW
2.2 3.0 4.7
5.3 Starting current with soft starter A 28 30 30
5.4 Nominal current A2 W35 / cosϕ A / --- 4.0 / 0.8 4.9 / 0.8 8.7 / 0.8
6 Complies with the European safety regulations
3
3. See CE declaration of conformity
33
7 Additional model features
7.1 Defrosting Automatic Automatic Automatic
Type of defrosting Reverse cycle Reverse cycle Reverse cycle
Defrosting tray included Yes (heated) Yes (heated) Yes (heated)
7.2 Heating water in device protected against icing
4
4. The heat circulating pump and the heat pump controller must always be ready for operation.
Yes Yes Yes
7.3 Performance levels 111
7.4 Controller internal/external External External External