MANUAL SELECTION SWITCH
Operates the electric fireplace in the same manner as
the remote control transmitter. Pressing the switch up
(“ I ” position) has the same effect as the ON button on
the remote control and pressing the switch down (“ II
position) has the same effect as the OFF button of the
remote control. Pressing the switch up once activates
Level 1, twice activates Level 2, three times activates
Level 3. Pressing the switch down turns the electric
fireplace OFF.
MAINTENANCE
WARNING
Disconnect power before attempting any maintenance or cleaning to reduce the risk of fire,
electric shock or damage to persons.
LIGHT BULB REPLACEMENT
WARNING
Allow at least 5 minutes for light bulbs to cool off before touching bulbs to avoid accidental
burning of skin.
Light bulbs need to be replaced when you notice a dark section of the flame or when the clarity
and detail of the log exterior disappears. There are two bulbs at the top of the opening which
illuminate the log set exterior, and four bulbs under the log set which generate the flames and
embers.
Tool Requirements: Slot Screw Driver
NOTE
Before replacing lamps unnecessarily, ensure that they are not simply loose or that the
brightness control is not adjusted to low setting (see item D in operation section).
To open the light bulb area:
1. Remove the trim by pulling straight forward.
2. Hold the glass in place while removing the retaining clip from the upper center of the
firebox.
3. Lift glass out and store in a safe place.
Level 1 Indicato
r
Level 2 Indicato
r
Level 3 Indicato
r