108382-01G 11
Hearth
5"
Min.
Combustible
Material
INSTALLATION
Continued
Figure 9 - Minimum Fireplace Clearances
Above Combustible Flooring
B. If combustible materials are less than 14" to the
replace, you must install appliance at least 5"
above the combustible ooring (see Figure 9).
INSTALLING DAMPER CLAMP
OPERATION
Note: When used as a vented heater, appliance
must be installed only in a solid-fuel burning
replace with a working ue and constructed of
noncombustible material.
If your heater is a manually controlled model, you may
use this heater as a vented product. There are three rea-
sons for operating your heater in the vented mode:
1. The replace does not meet the clearance to com-
bustibles requirements for vent-free operation
2. State or local codes do not permit vent-free
operation
3. You prefer vented operation
If reasons number 1 or 2 above apply to you, you
must permanently open chimney ue damper. You
must install the damper clamp accessory (to order,
see Accessories, page 25). This will insure vented
operation (see Figure 10). The damper clamp will
keep damper open. Installation instructions are
included with clamp accessory.
See chart below for minimum permanent ue
opening you must provide. Attach damper clamp
so the minimum permanent ue opening will be
maintained at all times.
Diameter Area
5" 20 sq. inches
6" 29 sq. inches
7" 39 sq. inches
8" 51 sq. inches
Minimum Permanent
6' to 15' 39 sq. inches
15' to 30' 29 sq. inches
Damper Clamp
Damper
Clamp
Damper
Damper
Manufactured
Figure 10 - Attaching Damper Clamp
CAUTION: Do not remove the
WARNING: You must secure
not, heater will move when you
-
-