TROUbLESHOOTING
Continued

Gas odor during combustion

1. Foreign matter between con-
trol valve and burner
2. Gas leak.  

REMEDY
1. Take apart gas tubing and
remove foreign matter
2. Locate and correct all leaks
(see Checking Gas Connec-
tions, page 14)

 
 
 

 -

 
IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint,
paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These
fumes may mix with combustion air and create odors. These odors will disappear over time.
ACCESSORIES
Purchase these heater accessories from your local
dealer. If they can not supply these accessories,
call DESA Heating Products at 1-866-672-6040
for referral information. You can also write to the
address listed on the back page of this manual.


Equipment shutoff valve with
1/8" NPT tap. Fits 1/2" pipe.
FIREPLACE HOOD



Helps deect heat away from mantel or wall above
replace. Fits opening 28" to 4" wide.

HELD THERMOSTAT
REMOTE CONTROL

Allows the replace to be operated in a manually or ther-
mostatically controlled mode. You can turn the replace
on and off without ever leaving the comfort of your easy
chair. A wall-mount docking station is included.

HELD REMOTE CONTROL

Allows the replace to be turned on and off by
using a hand-held remote control. A wall-mount
docking station is included.
WALL-MOUNT THERMOSTAT

The desired comfort setting can be selected on the
wall thermostat and the log heater will automatically
cycle from pilot to the heat setting selected.
WALL-MOUNT ON/OFF SWITCH

Allows the gas log heater to be turned on and off
with a wall switch.


Permanently opens chimney flue damper for
vented operation. Can be used only with non-
thermostat accessories.
CLEANING KIT - GCK 
Your vent-free gas appliance requires regular cleaning
and maintenance to prevent performance problems.
This kit gives you the tools and instructions to make it
easy to clean all critical areas of your appliance.

A care and maintenance video is available by
calling 1-866-672-6040. You may also email your
request to .


Creates the sound of a real burning re.

