Desa VYM27NRPR Water Heater User Manual


 
110398-01A
For more information, visit www.desatech.com
For more information, visit www.desatech.com
16
GHRCTA Series Operation
2b. Press the AUTO/ON/OFF button on the hand-held remote
control (see Figure 26). The lights to the left of the button
will show AUTO, ON, or OFF.
In the ON mode, the burners will ignite. The heater is in
manual mode when ON is lit.
In the AUTO mode, the thermostat in the hand-held re-
mote unit controls the room temperature. To increase the
room temperature, press the top arrow of the TEMP but-
ton. To lower the room temperature, press the bottom
arrow of the TEMP button. At higher settings the heater
will run longer.
IMPORTANT:
This remote control has been specially en-
gineered to take an air temperature sample every 5.5
minutes in the AUTO mode. It will not respond immedi-
ately to the temperature setting being turned up or down.
IMPORTANT:
The hand-held remote control unit must
be near the heater. Do not keep the hand-held remote
control unit too close to the heater. The thermostat on
the hand-held remote control unit will heat up too quickly
and turn the heater off.
3. To turn the burner off, press the AUTO/ON/OFF button
until OFF lights. The pilot will remain lit.
IMPORTANT:
To turn the pilot off, manually turn the con-
trol knob on the heater to the OFF position.
OPERATING HEATER
Optional Remote Operation (Cont.)
INSPECTING BURNERS
Pilot Flame Pattern
Burner Flame Pattern
OPERATING HEATER
Continued
Figure 26 - Thermostat Hand-Held Remote Control Unit
Selections (GHRCTA only)
Figure 25 - Setting the Selector Switch, Control Knob, and
Flame Adjustment Knob for Remote Operation
Selector Switch in Remote Position
(Optional Remote Control)
ON
OFF
REMOTE
O
F
F
P
I
L
O
T
O
N
L
O
I
H
Control Knob in
On Position
Flame Adjustment Knob
Increases Room
Temperature in
AUTO Mode
Decreases Room
Temperature in
AUTO Mode
Turns Burners
On or Off and
Allows You to
Choose the Auto
Setting
Shows
Temperature
Setting
The Log Heater
will Automatically
Cycle between
Pilot and the Heat
Setting that has
been Selected
Figure 27 - Correct Pilot Flame Pattern (Propane/LP Pilot Shown)
Pilot Burner
Thermocouple
Figure 28 - Incorrect Pilot Flame Pattern (Propane/LP Pilot
Shown)
Check pilot flame pattern and burner flame patterns often.
PILOT FLAME PATTERN
Figure 27 shows a correct pilot flame pattern. Figure 28 shows an
incorrect pilot flame pattern. The incorrect pilot flame is not
touching the thermocouple. When the thermocouple cools, the
heater will shut down.
If pilot flame pattern is incorrect, as shown in Figure 28
turn heater off (see To Turn Off Gas to Appliance, page 15)
see Troubleshooting, pages 18 through 20
Note:
The pilot flame on natural gas units will have a slight curve,
but flame should be blue and have no yellow or orange color.
Pilot Burner
INSPECTING BURNERS
Thermocouple
BURNER FLAME PATTERN
Figure 29 shows a correct burner flame pattern. Figure 30 shows an
incorrect burner flame pattern. If burner flame pattern is incorrect,
turn heater off (see To Turn Off Gas to Appliance, page 15)
see Troubleshooting, pages 18 through 20
Figure 29 - Correct Flame Pattern