VENTING INSTALLATION
INSTRUCTIONS
Continued
HIGH ALTITUDE INSTALLATION
Your DESA direct-vent replace has been CSA tested and approved
for elevations from 0-2000 feet (USA) and elevations from 0-4500
feet (Canada).
When installing this replace at an elevation above 2000 feet (in
the USA), you may need to decrease the input rating by changing
the existing burner orice to a smaller size. Reduce input 4% for
each 1000 feet above sea level. Check with your local gas company
for proper orice size identication.
When installing this replace at an elevation above 4500 feet (in
Canada), check with local authorities.
Consult your local gas company to help determine the proper orice
for your location.
For assistance with any high altitude installation contact DESA
Customer Service Department at 1-866-672-6040.
PARTS LISTS FOR VENTING KITS AND
DESA Pipe & Vent Kits
Number Description
P58-6 6" Section Double Wall Pipe - Galvanized
P58-12 12" Section Double Wall Pipe - Galvanized
P58-24 24" Section Double Wall Pipe - Galvanized
P58-36 36" Section Double Wall Pipe - Galvanized
P58-48 48" Section Double Wall Pipe - Galvanized
PA58-712 Adjustable 7"-12" Section Coaxial Pipe - Galvanized
FPA58-6 6" Duravent Collar to FMI Pipe Adaptor (6" Collar/Pipe
Section)
DPA58-6 6" FMI Collar to Pipe Duravent Adaptor (6" Collar/Pipe
Section
E58-45 45° Elbow, Galvanized
E58-90 90° Elbow, Galvanized
FSE58-45 45° Starter Elbow, Galvanized (Duravent Collar to FMI
Pipe)
DSE58-45 45° Starter Elbow, Galvanized (FMI Collar to Duravent
Pipe)
VKG-58 Ground Floor Vent Kit - Galvanized
VKB-58 Basement Vent Kit - Galvanized
VKS-58 Snorkel Kit - Galvanized
VKR-58 Roof Vent Kit - Galvanized
VKC-58 Corner Vent Kit - Galvanized
HTK Horizontal Round Termination Kit
HT-58 Horizontal Round Termination Kit, Galvanized
HTKS-58 Horizontal Square Termination Kit
HTS-58 Horizontal Square Termination Kit, Galvanized
VT-58 Vertical Round Termination, Galvanized
ST-58-14 14" Snorkel Termination, Galvanized
Number Description
ST-58-36 36" Snorkel Termination, Galvanized
SC-58 Storm Collar - Galvanized
WF-58 Wall Firestop - Galvanized
RF-58-6 Roof Flashing - 0 to 6/12 Pitch - Galvanized
RF-58-12 Roof Flashing - 6/12 to 12/12 Pitch - Galvanized
VR-58 Vertical Restrictor - Galvanized
S-58 Vinyl Siding Standoff - Galvanized
WS-58 Wall Strap
CS-58 Cathedral Ceiling Support
FP-58 Firestop Plate
SF-58 Stucco Flashing - For use with HTS-5
FIREPLACE INSTALLATION
Use proper gas type for the replace unit you are installing. If you
have conicting gas types, do not install replace. See retailer
where you purchased the replace for proper replace according
to your gas type.
INSTALLING OPTIONAL BLOWER
gas connections, shut off gas supply and disconnect
person to do this.
WARNING: If there is a duplex electrical outlet in-
base area, be sure that the electrical power to the outlet
is turned off before proceeding with blower installation.
Failure to do this may result in serious injury.
Model BK Installation
Follow all instructions provided in the blower accessory kit.
1. Attach the power cord to the blower motor by rmly pushing
the two female terminals at the end of the power cord onto the
two spade terminals on the blower motor (see Figure 25).
Figure 25 - Blower Model BK
Magnetic
Strips
Exhaust
Port
Screw
Green
Ground Wire
Spade
Terminals
Side View
Lower Firebox
Cavity
Blower
Location