Desa CGEFP33PR, CGEFP33NR, EFP33PR, EFP33NR, VTGF33NR, VTGF33PR Indoor Fireplace User Manual


 
108117-01G
For more information, visit www.desatech.com
For more information, visit www.desatech.com
3
3
SAFETY INFORMATION
PRODUCT IDENTIFICATION
1. This appliance is only for use with the type of gas indicated on
the rating plate. This appliance is not convertible for use with
other gases.
2. Do not place propane/LP supply tank(s) inside any structure.
Locate propane/LP supply tank(s) outdoors.
3. If you smell gas
shut off gas supply
do not try to light any appliance
do not touch any electrical switch; do not use any phone in
your building
immediately call your gas supplier from a neighbor’s phone.
Follow the gas supplier’s instructions
if you cannot reach your gas supplier, call the fire department
4. This fireplace shall not be installed in a bedroom or bathroom.
5. Do not use this fireplace as a wood-burning fireplace. Use only
the logs provided with the fireplace.
6. Do not add extra logs or ornaments such as pine cones, ver-
miculite, or rock wool. Using these added items can cause soot-
ing. Do not add lava rock around base. Rock and debris could
fall into the control area of fireplace.
7. To prevent the creation of soot, follow the instructions in Clean-
ing and Maintenance, page 28.
8. Before using furniture polish, wax, carpet cleaner, or similar
products, turn heater off. If heated, the vapors from these prod-
ucts may create a white powder residue within burner box or
on adjacent walls or furniture.
9. This fireplace needs fresh air ventilation to run properly. This
fireplace has an Oxygen Depletion Sensing (ODS) safety
shutoff system. The ODS shuts down the fireplace if not enough
fresh air is available. See Air for Combustion and Ventilation,
pages 5 through 7. If fireplace keeps shutting off, see Trouble-
shooting, pages 29 through 31.
10. Do not run fireplace
where flammable liquids or vapors are used or stored
under dusty conditions
11. Do not use this fireplace to cook food or burn paper or other
objects.
12. Do not use fireplace if any part has been exposed to or under
water. Immediately call a qualified service technician to in-
spect the fireplace and to replace any part of the control sys-
tem and any gas control which has been under water.
13. Do not operate fireplace if any log is broken. Do not operate
fireplace if a log is chipped (dime-sized or larger).
14. Turn fireplace off and let cool before servicing. Only a quali-
fied service person should service and repair fireplace.
15. Operating fireplace above elevations of 4,500 feet could cause
pilot outage.
16. To prevent performance problems with propane/LP units, do
not use propane/LP fuel tanks of less than 100 lb. capacity.
17. Provide adequate clearances around air openings.
SAFETY INFORMATION
Continued
PRODUCT IDENTIFICATION
Figure 2 - Fireplace (EFP33PR Shown)
Top Louver
Assembly
Firebox
Hood
Bottom Louver
Assembly
Screen
Assembly
Top Outer
Casing
Firebox Support
Blower
Assembly
(Optional)
Log Set
Wall Switch/Plate
Piezo
Ignitor
Remote
Control
Manual
Override
Handle
Manual Ignition
Bypass Switch
Figure 1 - Fireplace Floor Assembly (EFP33PR Shown)