108117
For more information, visit www.desatech.com
For more information, visit www.desatech.com
32
SPECIFICATIONS
Btu (Variable) 20,000/33,000
Type Gas Natural: (CG)EFP33NR, VTGF33NR
Propane/LP: (CG)EFP33PR, VTGF33PR
Ignition Electronic (Automatic)/Piezo (Manual)
Natural Gas Propane/LP Gas
Manifold Pressure 3.5" W.C.8.0" W.C.
Inlet Gas Pressure (in. of water)
Maximum 10.5" 14"
Minimum* 5" 11"
Shipping Weight 122 lbs. 122 lbs.
* For input adjustment
SERVICE HINTS
When Gas Pressure Is Too Low
• pilot will not stay lit
• burners will have delayed ignition
• heater will not produce specified heat
• for propane/LP units, propane/LP gas supply may be low
You may feel your gas pressure is too low. If so, contact your local
natural or propane/LP gas supplier.
TECHNICAL SERVICE
You may have further questions about installation, operation, or
troubleshooting. If so, contact DESA International’s Technical
Service Department at 1-866-672-6040.
You can also visit DESA International’s technical service web site
at www.desatech.com.
REPLACEMENT PARTS
Note:
Use only original replacement parts. This will protect your
warranty coverage for parts replaced under warranty.
PARTS UNDER WARRANTY
Contact authorized dealers of this product. If they can’t supply
original replacement part(s), call DESA International’s Technical
Service Department at 1-866-672-6040.
When calling DESA International, have ready
• your name
• your address
• model and serial numbers of your fireplace
• how fireplace was malfunctioning
• type of gas used (propane/LP or natural gas)
• purchase date
Usually, we will ask you to return the part to the factory.
PARTS NOT UNDER WARRANTY
Contact authorized dealers of this product. If they can’t supply original
replacement part(s), call DESA International at 1-866-672-6040 for
referral information.
When calling DESA International, have ready
• model number of your fireplace
• the replacement part number
SPECIFICATIONS
SERVICE HINTS
TECHNICAL SERVICE
REPLACEMENT PARTS