Desa VTD-30N-JHB Electric Heater User Manual


 
www.desatech.com
114370-01D 9
INSTALLATION
Continued
4. Place log set assembly in center of replace
oor. Make sure front faces forward.
5. Install gas connector tube into gas supply t-
ting. Carefully shape tube to attach to adapter
tting being careful not to kink tube.
6. Install provided gas connector tube into the
gas inlet tting (see Figure 7, page 8).
7. Test for leaks following instructions under
Testing Burner for Leaks, page 10.
Repositioning Gas Inlet to Left Side of
Unit
1. Remove venturi and gasket by unscrewing
two screws under chassis (see Figure 8).
2. Unthread elbow fitting from orifice (see
Figure 8).
3. Remove orice and brackets by unscrewing two
screws on right side of unit (see Figure 8).
4. Install orice and brackets into left side of unit
using screws removed in step 1.
5. Install venturi and gasket under bottom burner
and into repositioned orice and brackets (see
Figure 8).
6. Thread elbow tting back into orice. Apply
thread sealant to orice threads (see Figure 8).
7. Install gas connector tube that comes with log
set into gas inlet tting (see Figure 8).
8. Install supplied brass adapter tting that comes
with log set into replace gas supply pipe. Use
thread sealant (see Figure 8).
9. Place log set assembly in center of replace
oor. Make sure front faces forward.
10. Install gas connector tube into gas supply t-
ting. Carefully shape tube to attach to adapter
tting. Be careful not to cause kinks in tube.
11. Test for leaks following instructions under
Testing Burner for Leaks, page 10.
TESTING BURNER FOR LEAKS
1. Generously apply noncorrosive leak detection
uid to all connections.
WARNING: Never check for
gas leaks with open ame.
2. Light burner with shutoff valve no more than
half open and holding a match slightly in front
of the pan (see Lighting Instructions).
3. Inspect all connections for bubbles, raw gas
odors, or flame from any area other than
burner. If leaks are detected, shut off gas valve
immediately. Tighten or reassemble the loose
connections using pipe joint compound until
burner system is leak free.
4. When nished testing, turn gas shutoff valve
OFF to extinguish all ames.
Figure 8 - Repositioning Gas Inlet to Left
Side of Unit
Outer
Bracket
Gasket
Venturi
Screws
Inner
Brackets
Orice
Elbow
Fitting
Elbow
Fitting
Inner Brackets
Orice
Gasket
Venturi
Screws
Chassis
Chassis