Desa (V)T36P SERIES Indoor Fireplace User Manual


 
www.desatech.com
108661-01F 5
B
C
A
FRAMING AND FINISHING
Figure 4 shows typical framing of this replace. Figure 5 shows fram-
ing for corner installation. All minimum clearances must be met.
For available accessories for this replace, see Accessories on page
31. If you are using a separate combustible mantel piece, refer to
Figure 6 for proper installation height. You can install noncombustible
mantels at any height above the replace. Note: Noncombustible
mantels may discolor!
PRE-INSTALLATION
PREPARATION
Continued
Figure 4 - Framing Clearances for Installation Against an
Exterior Wall
32" Models 36" Models
A 32
3
/8" 36
1
/8"
B 34
5
/8" 41
1
/4"
C 19" 23
1
/2"
C
B
A
D
E
F
G
Top of Louver Opening
3
2
1
4
5
6
7
Wall
A
B
E
F
G
H
D
C
Nailing Tabs
Figure 5 - Framing Clearances for Corner Installation
Ref. Mantel Ref. Mantel from Top
Depth of Louver Opening
1 14" (356 mm) A 16" (406 mm)
2 12" (305 mm) B 14" (356 mm)
3 10" (254 mm) C 12" (305 mm)
4 8" (203 mm) D 10" (254 mm)
5 6" (152 mm) E 8" (203 mm)
6 4" (101 mm) F 6" (152 mm)
7 2" (51 mm) G 4" (101 mm)
32" Models 36" Models
A 28
1
/2" 35
3
/4"
B 13
5
/8" 15"
C 39
3
/8" 49
5
/8"
D 9
1
/2" 10
3
/8"
E 9
7
/8" 13
3
/4"
F 34
3
/8" 41"
G 34
5
/8" 41
1
/4"
H 54
1
/8" 68
1
/2"
Figure 6 - Clearances for Combustible Mantels