Desa VSGF36NT Indoor Fireplace User Manual


 
www.desatech.com
113192-01D
15
Note: If adding the G8007 series brick liner acces-
sory, install it now. Follow instructions in G8007
accessory kit.
CAUTION: Do not pick up
log base assembly by burner.
This could damage burner. Only
handle base by grates.
3. Route gas line (provided by installer) from
equipment shutoff valve to fireplace. Route
flexible gas supply line through one of the
access holes.
NOTICE: Most building codes
do not permit concealed gas
connections. A flexible gas line
is provided to allow accessibility
from the fireplace (see Figure 16).
The flexible gas supply line con-
nection to the equipment shutoff
valve should be accessible.
4. Attach the flexible gas line to gas supply (see
Figure 16). Check tightness of flexible gas
line attached to gas regulator of fireplace (see
Figure 16).
5. Check all gas connections for leaks. See
Checking Gas Connections, page 16.
6. Replace log base assembly back into fireplace.
Feed flexible gas line into fireplace base area
while replacing log base assembly. Make sure
the entire flexible gas line is in fireplace base
area. Reattach log base assembly to fireplace
with screws removed in step 2.
INSTALLATION
Continued
Figure 15 - Removing Log Base
Assembly From Fireplace
Figure 16 - Attaching Flexible Gas Lines
Together
Flexible Gas Line
from Fireplace
Gas Regulator
To Fireplace
Gas Regulator
Equipment
Shutoff Valve
Provided by
Installer
Propane/LP
To External
Regulator
Natural Gas
To Gas Meter
WARNING: Use pipe joint
sealant that is resistant to liquid
petroleum (LP) gas.
We recommend that you install a sediment trap in
supply line as shown in Figure 14, page 14. Locate
sediment trap where it is within reach for clean-
ing. Install in piping system between fuel supply
and fireplace. Locate sediment trap where trapped
matter is not likely to freeze. A sediment trap traps
moisture and contaminants. This keeps them from
going into fireplace gas controls. If sediment trap
is not installed or is installed wrong, fireplace may
not run properly.
CONNECTING FIREPLACE TO GAS
SUPPLY
Installation Items Needed
5/16" hex socket wrench or nut-driver
Phillips screwdriver
sealant (resistant to propane/LP gas, not pro
-
vided)
1. Remove fireplace screen. Remove one screw
that holds fireplace screen in place for ship
-
ping. This screw is located near top left side
of screen. Discard screw. Lift fireplace screen
up and pull out to remove.
2. Remove screws that attach log base assembly
to fireplace (see Figure 15). Carefully lift up
log base assembly and remove from fireplace
(see Figure 15).