Desa VN30BTA Electric Heater User Manual


 
www.desatech.com
113061-01F8
Minimum
From
Sides Of
Heater
36"
2"
FLOOR
CEILING
Minimum
Minimum To
Top Surface
Of Carpeting,
Tile Or Other
Combustible
Material
6"
Left
Side
Right
Side
INSTALLATION ITEMS
Before installing heater, make sure you have the
items listed below.
for propane/LP gas, external regulator (supplied
by installer)
piping (check local codes)
sealant (resistant to propane/LP gas)
equipment shutoff valve *
ground joint union
test gauge connection*
sediment trap
tee joint
pipe wrench
* A CSA design-certied equipment shutoff valve
with 1/8" NPT tap is an acceptable alternative to
test gauge connection. The optional CSA design-
certied equipment shutoff valve can be purchased
from your dealer. See Accessories, page 21.
LOCATING HEATER
WARNING: Maintain the
minimum clearances shown
in Figure 4. If you can, provide
greater clearances from oor,
ceiling and joining wall.
You can locate heater on the oor, away from a
wall. A wall mounting bracket and oor base stand
are included with this heater. Determine which
method is best for your application.
INSTALLATION
Continued
WARNING: Never install the
heater
• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture,
clothing or other ammable
objects are less than 36" from
the front, top or sides of the
heater
• as a replace insert
• in high trafc areas
• in windy or drafty areas
CAUTION: This heater cre-
ates warm air currents. These
currents move heat to wall sur-
faces next to heater. Installing
heater next to vinyl or cloth wall
coverings or operating heater
where impurities (such as, but
not limited to, tobacco smoke,
aromatic candles, cleaning u-
ids, oil or kerosene lamps, etc.) in
the air exist, may discolor walls
or cause odors.
IMPORTANT: Vent-free heaters add moisture to
the air. Although this is benecial, installing heater
in rooms without enough ventilation air may cause
mildew to form from too much moisture. See Air
for Combustion and Ventilation, page 5.
CAUTION: If you install the
heater in a home garage
• heater pilot and burner must
be at least 18" above oor
• locate heater where moving
vehicle will not hit it
For convenience and efciency, install heater
where there is easy access for operation, inspec-
tion and service
in coldest part of room
An optional fan kit is available from your dealer.
See Accessories, page 21. If planning to use fan,
locate heater near an electrical outlet.
Figure 4 - Mounting Clearances As
Viewed From Front of Heater