Desa VMH10TP Indoor Fireplace User Manual


 
26
103669
TROUBLE-
SHOOTING
Continued
OBSERVED
PROBLEM
Burner does not light
after ODS/pilot is lit
Delayed ignition of
burner
Burner backfiring
during combustion
Slight smoke or odor
during initial operation
Fireplace produces a
whistling noise when
burner is lit
POSSIBLE
CAUSE
1. Burner orifice is
clogged
2. Burner orifice diameter
is too small
3. Inlet gas pressure is
too low
1. Manifold pressure is
too low
2. Burner orifice is
clogged
1. Burner orifice is
clogged or damaged
2. Burner damaged
3. Low inlet gas pressure
4. Gas regulator defective
1. Residues from manu-
facturing processes
1. Air in gas line
2. Air passageways on
fireplace blocked
3. Dirty or partially
clogged burner orifice
REMEDY
1. Clean burner (see
Cleaning and Mainte-
nance, page 24) or
replace burner orifice
2. Replace burner orifice
3. Contact local propane/
LP gas company
1. Contact local propane/
LP gas company
2. Clean burner (see
Cleaning and Mainte-
nance, page 24) or
replace burner orifice
1. Clean burner (see
Cleaning and Mainte-
nance, page 24) or
replace burner orifice
2. Replace burner pressure
3. Contact local propane/
LP gas company
4. Replace gas regulator
1. Problem will stop after a
few hours of operation
1. Operate burner until air
is removed from line.
Have gas line checked
by local propane/LP gas
company
2. Observe minimum
installation clearances
(see Figures 6 and 7
page 11)
3. Clean burner (see
Cleaning and Mainte-
nance, page 24) or
replace burner orifice