Desa (V)K42N Indoor Fireplace User Manual


 
www.desatech.com
111921-01E22
TO TURN OFF GAS

1. Open lower louver panel.
2. Set selector switch in the OFF position to prevent draining
battery.
3. Turn off all electrical power to the appliance if service is to
be performed.
4. Push in gas control knob slightly and turn clockwise
to OFF.
5. Close lower louver panel.
Shutting Off Burners Only (pilot stays lit)
You may shut off the burners and keep the pilot lit by doing
one of the following:
1. Turn gas control knob clockwise to the PILOT
position.
2. Set selector switch in the OFF position.
MANUAL LIGHTING

1. Remove glass door (see Removing/Replacing Glass Door,
page 19.)
2. Follow steps 1 through 8 under Lighting Instructions,
page 21.
3. Depress gas control knob and light pilot with match.
4. Keep gas control knob pressed in for 30 seconds after light-
ing pilot. After 30 seconds, release gas control knob. Follow
steps 9 through 12 under Lighting Instructions, page 21.
5. Replace glass door (see Removing/Replacing Glass Door,
page 19).
O
F
F
P
I
L
O
T
L
O
I
H
O
N
Figure 49 - Control Valve
Piezo
Ignitor
Gas Control
Knob
Variable Control Knob
11. This valve is equipped with a HI/LO feature. Set replace
input as desired.
12. Close lower louver panel.
OPERATING FIREPLACE
Continued
OPTIONAL HAND-HELD
REMOTE OPERATION
Note: All remote control accessories must be purchased sepa-
rately (see Accessories, page 29). Follow instructions included
with the remote control.
        
hand-held remote control unit. See Lighting Instruc-
tions, page 21.
After lighting, let pilot ame burn for about one minute. Turn
control knob to ON position. Adjust ame adjustment knob
anywhere between HI and LO. Slide the selector switch to the
REMOTE position (see Figure 50). Note: The burner may light
if hand-held remote was on when selector switch was last turned
off. You can now turn the burner on and off with the hand-held
remote control unit.
IMPORTANT: Do not leave the selector switch in the REMOTE
or ON position when the pilot is not lit. This will drain the
battery.
Figure 51 - On/Off Hand-Held Remote Control Unit HRC100
Control
Button
Indicator
Light

Hold the control button on the hand-held remote until burner
turns on. Hold the control button again until burner turns off
(see Figure 51).
 press both buttons on hand-held remote control until
light stops ashing. Hand-held remote control is now locked. If
the re is on it will be turned off automatically. In the locked
state, the light will not light up when any button is pressed.
 press both buttons together on hand-held remote
control until the light stops ashing. The hand-held remote is
now unlocked.
O
F
F
P
I
L
O
T
L
O
I
H
ON
OFF
REMOTE
ON
OFF
O
N
Selector Switch in
Remote Position
Figure 50 - Setting the Selector Switch, Gas Control Knob
and Variable Control Knob for Remote Operation
Blower Control Knob
(Optional Accessory)
Gas Control Knob
in ON Position
Variable
Control Knob