Figure 35 - Checking Gas Joints for Natural Gas Fireplace
Figure 34 - Checking Gas Joints for Propane/LP Gas
Fireplace
Propane/LP
Supply Tank
Gas Valve
Equipment
Shutoff
Valve
Gas
Meter
Gas Valve
Equipment
Shutoff
Valve
3. Check all joints from propane/LP supply tank or gas meter to
equipment shutoff valve (see Figure 34 or 35). Apply noncor-
rosive leak detection uid to all joints. Bubbles forming show
a leak. Correct all leaks at once.
1. Open equipment shutoff valve (see Figure 33, page 17).
2. Open propane/LP supply tank valve for propane/LP replace
or main gas valve located on or near gas meter for natural gas
replace.
3. Make sure control knob of replace is in the OFF position.
4. Check all joints from equipment shutoff valve to gas valve (see
Figure 34 or 35). Apply noncorrosive leak detection uid to all
joints. Bubbles forming show a leak. Correct all leaks at once.
5. Light replace (see Operating Fireplace, page 21). Check all
other internal joints for leaks.
6. Turn off replace (see To Turn Off Gas to Appliance, page 22).
INSTALLING OPTIONAL WALL MOUNT
1. Connect one terminal of 25 ft. wire for wall switch to the TPTH
terminal on valve. Connect remaining wire terminal to TH
terminal on valve. Make sure wire terminals are in positions
on unit as pictured in Figure 36. If wires are not connected as
shown, switch will not work.
2. Route 25 ft. wire through openings provided on sides of burner
system to a convenient location to mount switch.
3. Connect one bare wire end to each of the terminals of the
GWMS2 wall switch.
4. Install wall switch and cover in wall.
Figure 36 - Connecting Wall Switch to Control Cover
To Wall
Thermostat
INSTALLING OPTIONAL WIRELESS HAND-
Installing Remote Receiver
1. Open bottom louver and locate the switch bracket on the left.
2. Unscrew the switch bracket. Lean bracket forward so you are
able to access the back of the remote receiver.
3. Locate the battery clip mounted on the back of the receiver.
Slide a 9-volt alkaline battery (not included) through the clip
(see Figure 37).
4. Attach the terminal wires to the battery.
5. Connect wires from receiver to TH and TPTH to control valve
(see Figure 38).
6. Replace the switch bracket.
Figure 37 - Attaching Alkaline Battery to Receiver
Figure 38 - Control Valve Terminals
To Optional
Remote
Accessory
9-Volt
Alkaline
Battery
Receiver
Terminal
Wires