TECHNICAL
SERVICE
You may have further questions about installation, operation, or troubleshooting.
If so, contact DESA International’s Technical Service Department at 1-800-323-
5190.
SPECIFICATIONS
B.T.U (Variable) 15,000/30,000
Type Gas Propane Only
Ignition Piezo
Pressure Regulator Setting 8" W.C.
Inlet Gas Pressure (inches of water)
Maximum 14"
Minimum 11"
Dimensions, Inches (H x W x D)
Heater 23.5 x 25.9 x 8.0
Carton 25.8 x 28.7 x 10.1
Weight (pounds)
Heater 30
Shipping 35
When gas pressure is too low
• pilot will not stay lit
• burner will have delayed ignition
• heater will not produce specified heat
• propane gas supply may be low
When gas quality is bad
• pilot will not stay lit
• burner will produce flames and soot
• heater will backfire when lit
You may feel your gas pressure is too low or gas quality is bad. If so, contact your
local propane gas supplier.
SERVICE
HINTS