Desa VGP30 Electric Heater User Manual


 
15
TO TURN OFF GAS TO APPLIANCE
Clockwise
Continued
Figure 17 - Incorrect Pilot Flame Pattern
Thermocouple
Pilot Burner
Clockwise
INSPECTING
BURNER
Check pilot flame pattern and burner flame pattern often.
PILOT FLAME PATTERN
Figure 16 shows a correct pilot flame pattern. Figure 17 shows an incorrect pilot
flame pattern. The incorrect pilot flame is not touching the thermocouple. This will
cause the thermocouple to cool. When the thermocouple cools, the heater will shut
down.
Figure 16 - Correct Pilot Flame Pattern
Thermocouple
Pilot Burner
Clockwise
Shutting Off Heater
1. Turn control knob clockwise to the PILOT position.
2. Press in control knob and turn clockwise to the OFF position.
3. Turn off all electric power to the appliance if service is to be performed.
Shutting Off Burner Only (pilot stays lit)
1. Turn control knob clockwise to the PILOT position.
MANUAL LIGHTING PROCEDURE
1. Remove front panel (see Figure 3, page 7).
2. Follow steps 1 thru 5 under LIGHTING INSTRUCTIONS, pages 13 and 14.
3. With control knob pressed in, strike match. Hold match to pilot until pilot lights.
4. Keep control knob pressed in for 30 seconds after lighting pilot. After 30
seconds, release control knob.
5. Replace front panel.