Desa VCGF30PR Indoor Fireplace User Manual


 
9
104637
OWNER’S MANUAL
35 1/2"
17 3/4"
33"
39 3/8"
27 7/8"
55 5/8"
35 1/2"
INSTALLATION
Continued
Figure 12 - Inserting Fireplace Into Cabinet
Mantel
Figure 11 - Location of Nailing Flanges
Nailing
Flanges
Continued
10. Carefully insert fireplace into cabinet
mantel. Be careful not to scratch or
damage hearth base, cabinet mantel, or
any laminate trim on hearth base. Re-
move protective material from top of
hearth base and from front of fireplace
(if any).
Note:
You can secure fireplace
to hearth or floor. Open lower louver.
Locate screw holes in bottom of base.
Tighten wood screws through these
holes and into hearth or floor.
11. Attach gas line from fireplace gas regu-
lator to gas supply. See Connecting
Fireplace to Gas Supply, page 11.
12. Check all gas connections for leaks. See
Checking Gas Connections, page 12.
BUILT-IN FIREPLACE
INSTALLATION
Built-in installation of this fireplace involves
installing fireplace into a framed-in enclo-
sure. This makes the front of fireplace flush
with wall. If installing a mantel above the
fireplace, you must follow the clearances
shown in Figure 16, page 10 . Follow the
instructions below to install the fireplace in
this manner.
Actual Framing
Height 32
3
/
8
" 33"
Front Width 34
5
/
16
" 35
1
/
2
"
Depth 16
11
/
16
" 17
3
/
4
"
1. Frame in rough opening. Use dimen-
sions shown in Figure 13 for the rough
opening.
If installing in a corner, use dimen-
sions shown in Figure 14 for the rough
opening. The height is 33" which is
the same as the wall opening above.
2. If using blower, install and properly
ground GA3555, three-prong 120 volt
electrical outlet, in fireplace. Follow
instructions included in kit (see Acces-
sories, pages 22 and 23).
3. Install gas piping to fireplace location.
This installation includes an approved
flexible gas line (if allowed by local
codes) after the equipment shutoff
valve. The flexible gas line must be
the last item installed on the gas pip-
ing. See Installing Gas Piping to Fire-
place Location, page 10.
4. Carefully set fireplace in front of
rough opening with back of fireplace
inside wall opening.
5. Attach flexible gas line to gas supply.
See Connecting Fireplace to Gas Sup-
ply, page 11.
6. Carefully insert fireplace into rough
opening.
7. Attach fireplace to wall studs using
nails or wood screws through holes in
nailing flange (see Figure 15).
8. Check all gas connections for leaks. See
Checking Gas Connections, page 12.
Figure 13 - Rough Opening for Installing
in Wall
Figure 14 - Rough Opening for Installing
in Corner
9. Plug electrical cord into electrical out-
let installed in step 2.
10. Install brass trim after final finishing
and/or painting of wall (see Figure 7,
page 8).
Figure 15 - Attaching Fireplace to Wall
Studs
Nailing Flanges
Nails or
Wood
Screws