OWNER’S MANUAL
SPECIFICATIONS
Golden Oak Golden Oak
Vintage Oak Vintage Oak and Birch and Birch
18" Variable 24" Variable 18" Variable 24, 30, and 36"
Manually Manually Manually Variable
Controlled Controlled Controlled Manually Controlled
Btu (Variable) 16,000/27,000 16,000/31,500 16,000/30,000 20,000/39,000
Type Gas Propane Only Propane Only Propane Only Propane Only
Ignition Piezo Piezo Piezo Piezo
Pressure Manifold 8.0" W.C. 8.0" W.C. 8.0" W.C. 8.0" W.C.
Inlet Gas Pressure (in. of water)
Maximum 14" 14" 14" 14"
Minimum* 11" 11" 11" 11"
* For input adjustment
Shipping Weight 27 lbs. 29 lbs. 28 lbs. 30 lbs. (24")/32 lbs. (30")
/34 lbs. (36”)
REPLACEMENT
PARTS
Note:
Use only original replacement parts.
This will protect your warranty coverage for
parts replaced under warranty.
Parts Under Warranty
Contact authorized dealers of this product.
If they can’t supply original replacement
part(s), call DESA International’s Techni-
cal Service Department at 1-800-323-5190.
When calling DESA International, have
ready
your name and address
model number of your heater
how heater was malfunctioning
type of gas used (propane or natural gas)
purchase date
Usually, we will ask you to return the defec-
tive part to the factory.
Parts Not Under Warranty
Contact authorized dealers of this product.
If they can’t supply original replacement
part(s), call DESA International’s Parts
Department at 1-800-972-7879 for referral
information. When calling DESA Interna-
tional, have ready
model number of your heater
the replacement part number
ACCESSORIES
Purchase these heater accessories from your
local dealer. If they can not supply these
accessories, call DESA International’s Parts
Department at 1-800-972-7879 for referral
information. You can also write to the ad-
dress listed on the back page of this manual.
MANUAL SHUTOFF
VALVE - GA5010
For all models. Manual shutoff valve with 1/8"
NPT tap. Fits 1/2" NPT pipe.
SERVICE HINTS
When gas pressure is too low
pilot will not stay lit
burners will have delayed ignition
heater will not produce specified heat
propane/LP gas supply may be low
When gas quality is bad
pilot will not stay lit
burners will produce flames and soot
heater will backfire when lit
You may feel your gas pressure is too low or
gas quality is bad. If so, contact your local
propane/LP gas supplier.
TECHNICAL
SERVICE
You may have further questions about in-
stallation, operation, or troubleshooting.
If so, contact DESA International’s Techni-
cal Service Department at
1-800-DESA LOG (1-800-337-2564).
BLACK FIREPLACE
HOOD - GA6050
For all models. Helps deflect heat away
from mantel or wall above fireplace. Fits
openings 28" to 48" wide.
BRASS FIREPLACE
HOOD - GA6052
For all models. Helps deflect heat away
from mantel or wall above fireplace. Fits
openings 28" to 48" wide.
DAMPER CLAMP - GA6080
For manually controlled models. Perma-
nently opens chimney flue damper for vented
operation.
LAVA ROCK - GA6060
For all models. Order when additional rock
is desired. (3 lb. bag)