Desa Unvented Propane Gas Log Heater Model Split Oak and American Oak Design Indoor Fireplace User Manual


 
22
103427
UNVENTED PROPANE GAS LOG HEATER
Note:
Use only original replacement parts.
This will protect your warranty coverage for
parts replaced under warranty.
Parts Under Warranty
Contact authorized dealers of this product.
If they can’t supply original replacement
part(s), call DESA International’s Techni-
cal Service Department at 1-800-323-5190.
When calling DESA International, have
ready
your name
your address
model number of your heater
how heater was malfunctioning
type of gas used (propane or natural gas)
purchase date
Usually, we will ask you to return the defec-
tive part to the factory.
Parts Not Under Warranty
Contact authorized dealers of this product.
If they can’t supply original replacement
part(s), call DESA International’s Parts
Department at 1-800-972-7879 for referral
information.
When calling DESA International, have
ready
model number of your heater
the replacement part number
REPLACEMENT
PARTS
18" Thermostat- 24" Thermostat- 30" Thermostat-
Controlled Controlled Controlled
Btu (Variable) 16,000/26,000 20,000/33,000 21,500/36,000
Type Gas Propane Only Propane Only Propane Only
Ignition Piezo Piezo Piezo
Manifold Pressure 7.9" W.C. 7.9" W.C. 7.9" W.C.
Inlet Gas
Pressure (in. of water)
Maximum 14" 14" 14"
Minimum* 11" 11" 11"
* For purpose of input adjustment
Shipping Weight 26 lbs. 30 lbs. 34 lbs.
SPECIFICATIONS
18" Variable 24" Variable 30" Variable
Manually- Manually- Manually-
Controlled Controlled Controlled
Btu (Variable) 16,000/26,000 20,000/33,000 21,500/36,000
Type Gas Propane Only Propane Only Propane Only
Ignition Piezo Piezo Piezo
Manifold Pressure 7.9" W.C. 7.9" W.C. 7.9" W.C.
Inlet Gas
Pressure (in. of water)
Maximum 14" 14" 14"
Minimum* 11" 11" 11"
* For purpose of input adjustment
Shipping Weight 26 lbs. 30 lbs. 34 lbs.
TECHNICAL
SERVICE
You may have further questions about in-
stallation, operation, or troubleshooting.
If so, contact DESA International’s Techni-
cal Service Department at
1-800-DESA LOG (1-800-337-2564).
When gas pressure is too low
• pilot will not stay lit
• burners will have delayed ignition
• heater will not produce specified heat
• propane/LP gas supply may be low
When gas quality is bad
• pilot will not stay lit
• burners will produce flames and soot
• heater will backfire when lit
You may feel your gas pressure is too low or
gas quality is bad. If so, contact your local
propane/LP gas supplier.
SERVICE HINTS