Desa S26NT Stove User Manual


 
12
105683
VENT-FREE NATURAL GAS PEDESTAL STOVE
For more information, visit www.desatech.com
Figure 18 - Pilot
7. Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.
If control knob does not pop out when
released, contact a qualified service
person or gas supplier for repairs.
Note:
If pilot goes out, repeat steps 3
through 7. This heater has a safety inter-
lock system. Wait one (1) minute for sys-
tem to reset before lighting pilot again.
8. Turn control knob counterclockwise
C-clockwise
to desired heating level. The
burners should light. Set control knob
to any heat level between HI and LO.
TO TURN OFF GAS
TO APPLIANCE
1. Follow steps 1 through 5 under Light-
ing Instructions.
2. Depress control knob and light pilot
with match.
3. Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob. Now
follow step 8 in column 2.
Shutting Off Heater
Turn control knob clockwise
Clockwise
to
the OFF position.
Shutting Off Burners Only (pilot
stays lit)
Turn control knob clockwise
Clockwise
to
the PILOT position.
THERMOSTAT CONTROL
OPERATION
The thermostat control knob can be set to
any comfort level between Hi and Lo. The
thermostat will gradually modulate the heat
output and flame height from higher to
lower settings, or pilot, in order to maintain
the comfort level you select. The ideal com-
fort setting will vary by household depend-
ing upon the amount of space to be heated,
the output of the central heating system, etc.
Note:
Selecting the Hi setting with the
control knob will cause the burners to
remain fully on, without modulating down
in most cases.
MANUAL LIGHTING
PROCEDURE
Thermocouple
Pilot Burner
OPERATING
HEATER
Continued
INSPECTING
BURNERS
Check pilot flame pattern and burner flame
patterns often.
PILOT FLAME PATTERN
Figure 19 shows a correct pilot flame pat-
tern. Figure 20 shows an incorrect pilot
flame pattern. (
Note:
Appearance of pilot
assembly may vary by model). The incor-
rect pilot flame is not touching the thermo-
couple. This will cause the thermocouple to
cool. When the thermocouple cools, the heater
will shut down.
If pilot flame pattern is incorrect, as shown
in Figure 20
turn heater off (see To Turn Off Gas to
Appliance)
see Troubleshooting, pages 14 through 16
Figure 19 - Correct Pilot Flame Pattern
Figure 20 - Incorrect Pilot Flame Pattern
Thermocouple
Pilot Burner
Pilot Burner
Thermocouple
CAUTION: Do not try to adjust
heating levels by using the equip-
ment shutoff valve.
Ignitor Electrode
Figure 17- Control Knob and Ignitor
Button Location
1. STOP! Read the safety information,
page 11, column 3.
2. Make sure equipment shutoff valve
is fully open.
3. Turn control knob clockwise
Clockwise
to the OFF position.
4. Wait five (5) minutes to clear out any
gas. Then smell for gas, including
near the floor. If you smell gas,
STOP! Follow “B” in the safety in-
formation, page 11, column 3. If you
don’t smell gas, go to the next step.
5. Turn control knob counterclockwise
C-clockwise
to the PILOT position.
Press in control knob for five (5) sec-
onds (see Figure 17).
Note:
You may
be running this heater for the first
time after hooking up to gas supply.
If so, the control knob may need to
be pressed in for 30 seconds or less.
This will allow air to bleed from the
gas system.
6. With control knob pressed in, press
and release ignitor button. This will
light pilot. The pilot is attached to the
front burner. If needed, keep press-
ing ignitor button until pilot lights.
Note:
If pilot does not stay lit, con-
tact a qualified service person or gas
supplier for repairs. Until repairs are
made, light pilot with match. To light
pilot with match, see Manual Light-
ing Procedure.
LIGHTING
INSTRUCTIONS
NOTICE: During initial operation
of new heater, burning logs will
give off a paper-burning smell.
Orange flame will also be present.
Open a window to vent smell. This
will only last a few hours.
Control Knob
Ignitor Button