Desa RV125EDI Electric Heater User Manual


 
11
125 AIR FILTER REMOVAL
PFA/P 046
Air Output, Air Intake,
and Lint Filters
1. Remove upper shell (see
page 10).
2. Remove lter end cover
screws using 5/16" nut-
driver.
3. Remove lter end cover.
4. Replace air output and lint
lters.
5. Wash or replace air intake
lter (see Preventative
Maintenance Schedule,
page 8).
6. Replace lter end cover.
7. Replace fan guard and
upper shell.
IMPORTANT:
Do not oil
lters.
Figure 9 - Air Output, Air Intake, and Lint Filters
Air Intake Filter
Filter End
Cover
Air Output
Filter
Lint Filter
Fan Guard
Pump Pressure
Adjustment
1. Remove pressure gauge
plug from lter end cover.
2. Install accessory pressure
gauge (part number
HA1180).
3. Start heater (see Operation,
page 7). Allow motor to
reach full speed.
4. Adjust pressure. Turn relief
valve to right to increase
pressure. Turn relief valve
to left to decrease pressure.
Set pump pressure at 4 psi.
5. Remove pressure gauge.
Replace pressure gauge
plug in lter end cover.
Pressure
Gauge
Figure 11 - Adjusting Pump Pressure
Pressure
Gauge
Plug
Relief
Valve
Figure 10 - Pressure Gauge Plug Removal