6
101283
4. Open propane supply valve on propane tank(s) slowly.
Note:
If not opened
slowly, excess-flow check valve on propane tank will stop gas flow. If this
happens, close propane supply valve and open again slowly.
INSTALLATION
Continued
Figure 3 - Hose and Inlet Connector
LP-PFA/OV 008Hose and Inlet Connector-LP275
Figure 2 - Regulator With Vent Pointing Down
Propane
Tank
1. Provide propane supply system (see Propane Supply, page 5).
2. Connect POL fitting on hose/regulator assembly to propane tank(s). Turn
POL fitting counterclockwise into threads on tank. Tighten firmly using
7/8" wrench.
IMPORTANT:
Tighten regulator with vent pointing down.
Pointing vent down protects regulator from weather damage.
Supply Valve
POL Fitting
Hose
Regulator
Vent
(pointing down)
3. Connect hose to the inlet connector. Tighten firmly using 9/16" wrench.
IMPORTANT:
Use extra hose or piping if needed. Install extra hose or
piping between hose/regulator assembly and propane tank. You must use the
regulator supplied with heater even if propane tank has one.
Hose
Inlet Connector
WARNING ICON G 001
WARNING
Test all gas piping and connections for leaks after installation
or servicing. Never use an open flame to check for a leak.
Apply a mixture of liquid soap and water to all joints. Bubbles
forming show a leak. Correct all leaks at once.
WARNING ICON G 001
WARNING
Review and understand the warnings in the Safety Informa-
tion Section. They are needed to safely operate this heater.
Follow all local codes when using this heater.