12
100165
SERVICE
PROCEDURE
Continued
21. Connect motor wires as
follows (see Figure 6,
page 10):
• white wire—to terminal
board.
Note:
Attach to
empty connector on white
wire side of terminal
board.
• red wire—to terminal
board.
Note:
Attach to
empty connector on black
wire side of terminal
board.
• blue wire—to thermal
switch wire
• blue wire—to solenoid
valve
• green wire—to grounding
screw on shell
22. Replace side cover.
23. Replace fan guard.
Model
Input Rating (kJ/Hr) (BTU/Hr)
Fuel
Fuel Consumption
Gallons/Hour
Pounds/Hour
Supply Pressure To Regulator
Minimum (for purposes of
input adjustment)
Maximum
Regulator Outlet Pressure
Motor
Electric Input
Amperage
Weight
Heater
Shipping
Size - L x W x H
Heater
Carton
RCLP375 and BCLP375
168.800 to 332.325 (160,000 to 315,000)
Propane Vapor Only
6,8 l/h min./13,6 l/h max.
(1.8 Minimum/3.6 Maximum)
3,35kg/h min./ 6,85 kg/h max.
(7.4 Minimum/15.1 Maximum)
172 kPa (25 psig)
1379 kPa (200 psig )
48 - 138 kPa (7-20 psig)
1700 RPM
120 V/60 Hz
3.0
18, 1 kg (40 lbs.)
21,8 kg (48 lbs.)
89 cm x 33 cm x 51 cm (35 in. x 13 in. x 20 in.)
94 cm x 40,5 cm x 53,5 cm (37 in. x 16 in. x 21in.)
SPECIFICATIONS