Desa H.S.I. Series Electric Heater User Manual


 
9
102438
SERVICE
PROCEDURES
WARNING
!
Upper Shell Removal
1. Remove screws along each side of
heater using 5/16" nut-driver. These
screws attach upper and lower
shells together.
2. Lift upper shell off.
3. Remove fan guard.
Never service heater while it is plugged in, operating, or
hot. Severe burns and electrical shock can occur.
Air Output, Air Intake, and
Lint Filters
1. Remove upper shell (see above).
2. Remove lter end cover screws
using 5/16" nut-driver.
3. Remove lter end cover.
4. Replace air output and lint lters.
5. Wash or replace air intake lter
(see Preventative Maintenance
Schedule, page 7).
6. Replace lter end cover.
7. Replace fan guard and upper shell.
IMPORTANT:
Do not oil lters.
Fan
Guard
Upper
Shell
Figure 4 - Upper Shell Removal
Fan
Setscrew
Motor
Shaft
Motor
Figure 6 - Air Output, Air Intake, and Lint Filters
Fan
IMPORTANT:
Remove fan from motor
shaft before removing motor from
heater. The weight of the motor
resting on the fan could damage the
fan pitch.
1. Remove upper shell (see above).
2. Use 1/8" allen wrench to loosen
set-screw which holds fan to motor
shaft.
3. Slip fan off motor shaft.
4. Clean fan using soft cloth mois-
tened with kerosene or solvent.
5. Dry fan thoroughly.
6. Replace fan on motor shaft. Place
fan hub ush with end of motor
shaft (see Figure 5).
7. Place setscrew on at of shaft.
Tighten setscrew rmly (40-50
inch-pounds).
8. Replace fan guard and upper shell.
Figure 5 - Fan Cross Section
Fan Guard
Filter End Cover
Air Intake Filter
Lint Filter
Air Output Filter
Flush