Desa P325E(B), VP325E(B) Indoor Fireplace User Manual


 
108794
16
For more information, visit www.desatech.com
For more information, visit www.desatech.com
INSPECTING BURNERS
Pilot Burner
Ignitor/Sensor
Figure 35 - Correct Pilot Flame Pattern
Sensing Rod
Check pilot flame pattern and burner flame patterns often.
PILOT ASSEMBLY
The pilot assembly is factory preset for the proper flame. Alterations
may have occurred during shipping and handling. The pilot is
located on the back right hand side of the burner.
The flame must envelope 1/4" of top of the ignitor/sensor and
grounding stem.
If your pilot assembly does not meet these requirements:
Turn the adjustment screw marked PILOT clockwise to decrease
or counterclockwise to increase the flame to proper size (see
Figure 35). Do not remove the adjustment screw.
see Troubleshooting, pages 19 and 20
OPERATING FIREPLACE
To Turn Off Gas To Appliance
Optional Remote Operation
INSPECTING BURNERS
Pilot Assembly
Figure 33 - Turning Equipment Shutoff Valve to the OFF Position
10. Fully close glass doors if installed.
11. Turn on all electric power to the appliance.
12. Turn the wall switch to the ON position.
13. Visually locate the pilot. The ignitor should begin to spark
and the main burner should ignite once flame appears at
pilot.
If lighting the appliance for the first time each season, it
may take several attempts before the supply gas can reach
the pilot and main burners.
If the appliance will not stay lit after several attempts,
follow the instructions To Turn Off Gas To Appliance,
below, and call your service technician or gas supplier.
Equipment
Shutoff Valve
Adjustment
Screw
TO TURN OFF GAS
TO APPLIANCE
1. Turn off the wall switch.
2. Turn off all electric power to the appliance if service is to
be performed.
3. Fully open glass doors if installed.
4. Remove front hearth brick and control access panel.
5. Turn equipment shutoff valve clockwise
Clockwise
to OFF.
Do not force.
6. Replace front refractory brick access panel.
7. Fully close glass doors if installed.
Figure 34 - Pilot
Sensing Rod
Pilot Burner
Ignitor
OPTIONAL REMOTE OPERATION
Note:
The WRC receiver and hand-held remote control kit
must be purchased separately (see Accessories, page 21). Follow
installation instructions on page 10.
1. Turn equipment shutoff valve to ON position. You can now turn
the burner on and off with the hand-held remote control unit.
IMPORTANT:
Be sure to press the ON/OFF buttons on the
hand-held remote control unit for up to 3 seconds to assure
proper operation.
2. Press the ON/OFF button to turn the burner on and off.
OPERATING FIREPLACE
Continued