Desa LSF30NT Electric Heater User Manual


 
www.desatech.com
116307-01C4
5. This heater needs fresh, outside air ventilation
to run properly. This heater has an Oxygen
Depletion Sensing (ODS) safety shutoff
system. The ODS shuts down the heater if
not enough fresh air is available. See Air for
Combustion and Ventilation, page 5.
6. Keep all air openings in front and bottom of
heater clear and free of debris. This will insure
enough air for proper combustion.
7. If heater shuts off, do not relight until you
provide fresh, outside air. If heater keeps
shutting off, have it serviced.
8. Do not run heater
• where ammable liquids or vapors are used
or stored
• under dusty conditions
9. Do not use heater if any part has been under
water. Immediately call a qualied service
technician to inspect the room heater and to
replace any part of the control system and any
gas control which has been under water.
10. Turn off and unplug (if using electricity)
heater and let cool before servicing. Only a
qualied service person should service and
repair heater.
11. Operating heater above elevations of 4,500
feet (1,371 m) could cause pilot outage.
12.
To prevent performance problems, do not use
propane/LP fuel tank of less than 100 lbs. (45 kg)
capacity.
13. Before using furniture polish, wax, carpet
cleaner or similar products, turn heater off. If
heated, the vapors from these products may
create a white powder residue within burner
box or on adjacent walls or furniture.
14. Provide adequate clearances around air
openings.
LOCAL CODES
Install and use heater with care. Follow all local
codes. In the absence of local codes, use the lat-
est edition of The National Fuel Gas Code, ANSI
Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
SAFETY INFORMATION
Continued
Figure 1 - Vent-Free Gas Heater
Control Knob &
Ignitor Button
(inside door)
Front Panel
Grill
Guard
UNPACKING
1. Remove heater, front panel and grill from
carton. Set aside in a safe location.
2. Carefully remove refractory from heater and
remove packing material. Check refractory
for any damage. If the refractory is damaged
do not use. See Replacement Parts, page 21.
Set aside in a safe location.
3. Check heater for any damage. If heater is dam-
aged, promptly return to where you bought
heater.
PRODUCT FEATURES
SAFETY DEVICE
This heater has a pilot with an Oxygen Deple-
tion Sensing (ODS) safety shutoff system. The
ODS/pilot is a required feature for vent-free room
heaters. The ODS/pilot shuts off the heater if there
is not enough fresh air.
IGNITION SYSTEM
This heater has either a piezo ignitor or electronic
ignitor to light heater fuel supply.
THERMOSTATIC HEAT CONTROL
Thermostat models have a thermostat sensing
bulb and a control valve. This results in the great-
est heater comfort. This can also result in lower
gas bills.
PRODUCT
IDENTIFICATION