INSTALLATION
Continued
CAUTION: Make sure exter-
Con-
necting to Gas Supply
1.
Disconnect appliance with its appliance main
gas valve (control valve) and equipment shutoff
valve from gas supply piping system. Pressures in
excess of 1/2 psig will damage heater regulator.
2. Cap off open end of gas pipe where equipment
shutoff valve was connected.
3. Pressurize supply piping system by either
opening propane/LP supply tank valve for
propane/LP gas or opening main gas valve
located on or near gas meter for natural gas or
using compressed air.
4. Check all joints of gas supply piping system.
Apply a noncorrosive leak detection uid to
gas joints. Bubbles forming show a leak.
5. Correct all leaks at once.
6.
Reconnect heater and equipment shutoff valve to
gas supply. Check reconnected ttings for leaks.
1. Close equipment shutoff valve (see Figure 24).
2. Pressurize supply piping system by either
opening propane/LP supply tank valve for
propane/LP gas or opening main gas valve
located on or near gas meter for natural gas
or using compressed air.
3. Check all joints from gas meter for natural or
propane/LP supply to equipment shutoff valve
(see Figures 25 and 26). Apply a noncorrosive
leak detection uid to gas joints. Bubbles
forming show a leak.
4. Correct all leaks at once.
Figure 24 - Equipment Shutoff Valve
Open
Closed
Equipment
Shutoff
Valve
Figure 25 - Checking Gas Joints Shown
with Optional Mantel (Propane/LP Gas)
Equipment Shutoff Valve
Propane/LP
Supply
Tank
Figure 26 - Checking Gas Joints Shown
with Optional Mantel (Natural Gas)
Gas Meter
Equipment Shutoff Valve
CONNECTIONS
1.
Open equipment shutoff valve (see Figure 24).
2. Open main gas valve located on or near gas
meter for natural gas or open propane/LP
supply tank valve.
3. Make sure control knob of replace is in the
OFF position.
4. Check all joints from equipment shutoff valve
to thermostat gas valve (see Figures 25 and
26). Apply a noncorrosive leak detection uid
to gas joints. Bubbles forming show a leak.
5. Correct all leaks at once.
6. Light replace (see Operating Fireplace, page
18). Check all other internal joints for leaks.
7. Turn off replace (see To Turn Off Gas to
Appliance, page 19).