www.desatech.com
119508-01A16
INSTALLATION
Continued
CONTROL
Installation Items Needed
• Phillips screwdriver
• sealant (resistant to propane/LP gas, not
provided)
1. Remove replace screen. Remove two screws
that hold replace screen in place for shipping.
These screws are located near top of screen.
Discard screws. Lift replace screen up and
pull out to remove.
2. Remove screws that attach branch support
to replace (see Figure 22). Carefully lift up
branch support and remove from replace (see
Figure 22).
3. Route exible gas line, included, from replace
control to equipment shutoff valve through side
or rear access holes in outer casing.
-
4. Apply pipe joint sealant lightly to male threads
of gas connector attached to exible gas line/
equipment shutoff valve (see Figure 23).
5. Check all gas connections for leaks. See
Checking Gas Connections.
6. Replace branch support back into replace.
Feed exible gas line into replace base area
while replacing branch support. Make sure
the entire exible gas line is in replace base
area. Reattach branch support to replace with
screws removed in step 2.
Figure 22 - Removing Log Base
Assembly From Fireplace
Branch
Support
Screen
Screen
Shipping
Screw
Shoulder
Screw
Flexible
Gas Line
Figure 23 - Attaching Flexible Gas Line
to Equipment Shutoff Valve
Flexible Gas Line from
Fireplace Gas Regulator
Provided with Fireplace
To Fireplace
Gas Regulator
Equipment Shutoff
Valve Provided by
Installer
and connections, internal and
external to unit, for leaks after
WARNING: Never use an
-
To External
Regulator
NATURAL
To Gas Supply