Desa HRC100 Indoor Fireplace User Manual


 
www.desatech.com
113109-01G20
O
F
F
P
I
L
O
T
L
O
I
H
AU TO
OFF
ON
O
N
Figure 32 - Control Knob and Ignitor
Button Location (Shown as Supplied, No
Control Options)
Control Knob
Ignitor Button
Selector Switch
Flame Adjustment
Knob
4. Press in and turn control knob clockwise
to the OFF position.
5. Wait ve (5) minutes to clear out any gas.
Then smell for gas, including near the
oor. If you smell gas, STOP! Follow “B”
in the safety information
, page 19
. If you
don’t smell gas, go to the next step.
6. Press in and turn control knob counter-
clockwise to the PILOT position.
Press in control knob for ve (5) seconds
(see Figure 32).
Note: You may be running this heater for
the rst time after hooking up to gas sup-
ply. If so, the control knob may need to be
pressed in for 30 seconds or more. This will
allow air to bleed from the gas system.
7. With control knob pressed in, press and
release ignitor button. This will light pilot.
The pilot is attached to the front burner. If
needed, keep pressing ignitor button until
pilot lights.
Note: If pilot does not stay lit, contact a
qualied service person or gas supplier for
repairs. Until repairs are made, light pilot
with match. To light pilot with match, see
Manual Lighting Procedure, page 21.
8. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob.
• If control knob does not pop out when
released, contact a qualied service
person or gas supplier for repairs.
Note: If pilot goes out, repeat steps 4
through 8.
9. Slightly push in and turn control knob coun-
terclockwise to the ON position.
10. Wait one minute and switch selector
switch to the ON position to light burner.
Figure 33 - Pilot (Propane/LP)
Ignitor
Electrode
Pilot Burner
Figure 34 - Pilot (Natural)
Pilot Burner
Ignitor
Electrode
OPERATION
Continued
11. Set ame adjustment knob to any level
between HI and LO.
12. To leave pilot lit and shut off burners only:
turn control knob clockwise to the
PILOT position, or use remote control
manual OFF button, or set selector switch
in the OFF position.
CAUTION: Do not try to ad-


WARNING: Make sure the
selector switch is in the OFF


-
cally with selector switch in the

TO TURN OFF GAS
TO APPLIANCE
1. Turn control knob clockwise to the
OFF position.
2a. Set selector switch in the OFF position.
2b. If Using Optional Hand-Held Remote: Set
selector switch in the OFF position to keep
from draining the battery.
3. Close equipment shutoff valve (see Fig-
ure 21, page 16).