Desa GVR50BPA Water Heater User Manual


 
34
100791
SERVICE
PROCEDURES
Continued
Changing Burner Orifice
1. Shut off gas supply to
heater.
2. Remove lower front
access panel on heater.
3. Disconnect burner tube
from orifice holder (see
Figure 25).
4. Remove orifice holder
from burner (see Figure
25).
5. Use socket or open-end
wrench to remove the old
orifice from the orifice
holder.
6. Clean and replace orifice,
or replace with new
orifice.
7. Turn on gas to heater and
check for gas leaks. Apply
a mixture of liquid soap
and water to all joints.
Bubbles forming show a
leak. Correct all leaks at
once.
8. Replace lower front
access panel.
Figure 25 - Orifice Location (35,000 BTU/Hr Burner Shown)
Burner
Tube
Orifice
Holder
Orifice
Burner
Figure 26 - Orifice
BLOWER
WIRING
DIAGRAM
(For Models With
Blower Assembly)
Black Blue
Fan Switch
(Off/On/Auto)
Red
Fan
Switch
(N.O.)
Black
Red
White
Green
White
On
110/115 V.A.C.
Blower
Motor
Black
Off
Auto