INSTALLING
HEATER
Continued
INSTALLING RADIANTS
WARNING ICON G001
WARNING
Carefully handle the glass panel. Glass edges are
rounded and buffed to prevent cuts, however, chipped
or broken sections of glass can present sharp edges.
These sharp edges can cut skin.
1. Remove glass guard from across opening at front of heater (see Figure 9).
2. Place radiants into combustion chamber through opening at front of heater.
Front of radiant sits on front radiant support (see Figure 10). Back of radiant
rests on back radiant support (see Figures 9 and 10).
Note:
Radiants should never come in contact with burner flame. Contact with
flame may cause carbon or soot deposits on radiants.
Burner
Combustion
Chamber
Back Radiant
Support
Lower Front
Access Area
Glass
Guard
Lower
Front Access
Panel
Glass Retaining
Channel
Figure 9 - Location of Radiants
Back Radiant Support
Radiant
Burner
Front Radiant Support
Figure 10 - Position of Radiant