104415-01J
For more information, visit www.desatech.com
For more information, visit www.desatech.com
4
LOCAL CODES
Install and use heater with care. Follow all local codes. In the
absence of local codes, use the latest edition of The National Fuel
Gas Code ANSI Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
Note:
Where listed vented decorative logs are required, thermostat
operation is not permitted.
1. Remove logs and heater base assembly from carton.
Note:
Do
not pick up heater base assembly by burners. This could dam-
age heater. Always handle base assembly by grate.
2. Remove all protective packaging applied to logs and heater
for shipment.
3. Check all items for any shipping damage. If damaged, promptly
inform dealer where you bought heater.
UNPACKING
CAUTION: Do not remove the data plates from the
grate assembly. The data plates contain important
warranty and safety information.
AIR FOR COMBUSTION AND
VENTILATION
Today’s homes are built more energy efficient than ever. New mate-
rials, increased insulation, and new construction methods help reduce
heat loss in homes. Home owners weather strip and caulk around
windows and doors to keep the cold air out and the warm air in. During
heating months, home owners want their homes as airtight as possible.
While it is good to make your home energy efficient, your home
needs to breathe. Fresh air must enter your home. All fuel-burning
appliances need fresh air for proper combustion and ventilation.
Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances
draw air from the house to operate. You must provide adequate fresh
air for these appliances. This will insure proper venting of vented
fuel-burning appliances.
WARNING: This heater shall not be installed in a
confined space or unusually tight construction un-
less provisions are provided for adequate combus-
tion and ventilation air. Read the following instruc-
tions to insure proper fresh air for this and other
fuel-burning appliances in your home.
PROVIDING ADEQUATE VENTILATION
The following are excerpts from National Fuel Gas Code, ANSI
Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation.
All spaces in homes fall into one of the three following ventilation
classifications:
1. Unusually Tight Construction
2. Unconfined Space
3. Confined Space
The information on pages 4 through 6 will help you classify your
space and provide adequate ventilation.
Unusually Tight Construction
The air that leaks around doors and windows may provide enough
fresh air for combustion and ventilation. However, in buildings of
unusually tight construction, you must provide additional fresh air.
OPTIONAL REMOTE CONTROL ACCESSORIES
LOCAL CODES
UNPACKING
PRODUCT FEATURES
AIR FOR COMBUSTION AND VENTILATION
Providing Adequate Ventilation
OPTIONAL REMOTE
CONTROL ACCESSORIES
PRODUCT FEATURES
OPERATION
This heater is clean burning. It requires no outside venting. There is
no heat loss out a vent or up a chimney. Heat is generated by both
realistic flames and glowing coals. This heater is designed for vent-
free operation with flue damper closed. It has been tested and
approved to ANSI Z21.11.2 standard for unvented heaters. State and
local codes in some areas prohibit the use of vent-free heaters. This
heater may also be operated as a vented decorative (ANSI Z21.60)
product by opening the flue damper (Non-Thermostat Models Only).
SAFETY DEVICE
This heater has a pilot with an Oxygen Depletion Sensing (ODS)
safety shutoff system. The ODS/pilot is a required feature for vent-
free room heaters. The ODS/pilot shuts off the heater if there is not
enough fresh air.
PIEZO IGNITION SYSTEM
This heater has a piezo ignitor. This system requires no matches,
batteries, or other sources to light heater.
There are four optional remote controls that can be purchased
separately for Remote-Ready Models Only:
• wall switch • hand-held ON/OFF remote
• wall thermostat • hand-held thermostat remote.
See Accessories, page 36.
The wall thermostat or hand-held thermostat may not be used where
vented decorative listing is required.